AG Neovo ATP/AST Series User Manual

Page of 13
 
 
Rev. 10©1999 - 2006 DMC Co., Ltd. 
ATP/AST Series Product Specifications
3. Reliability Condition 
3-1. Temperature Condition 
§ Temperature Condition Test 
Following test are performed in the condition with no dew condensation: 
Cold Test: 
Tested after leaving the parts in -30°C
±3°C for 240 hours and in the room temperature 
for 2 hours. 
Heat Test: 
Tested after leaving the parts in 80°C
±3°C for 240 hours and in the room temperature for 
2 hours. 
Humidity Test:  Tested after leaving the parts in the temperature 60°C
±3°C, humidity 90 to 95% for 240 
hours and in the room temperature for 2 hours. 
Cycle Test: 
Tested after 5 cycles of leaving the parts in the temperature -30°C
±3°C for 1 hour and in 
the room temperature for 0.5 hours, then leaving the parts in the temperature 70°C
±3°C 
for 1 hour and in the room temperature for 0.5 hours. 
Judgement: 
Must satisfy the following: 
Activation Force: 
Within 
±50% of the specification. 
Linearity: 
Must satisfy the specification. 
Terminal Resistance: 
Must satisfy the specification. 
Insulation Resistance: 
Must satisfy the specification. 
Appearance: 
Must satisfy the specification. 
 
 
 
4. Recommended Connector 
4-1. Recommended Connector 
Part No. 
Pins 
Pitch 
KCA-K4R 
4 pin Double-sided 
1.25mm