Build – Check Polygons – Element
Checking for Illegal Polygons in Element
This command is used to check for illegal polygons among those comprising the selected element.
 Operating Procedure 
1
  From the element list, select one desired 
element.
2
  From the [Build] menu, select [Check 
Polygons] then click [Element].
The [Build-Check Polygons-Element] dialog 
box will appear.
•  The selected element will be ready to be dis-
played in all windows. It will be displayed if 
it is not displayed in the active window or the 
windows for which all the elements are set to be 
displayed.
Note
An error message will appear if more than one element
is selected.
3
  Check the checkboxes of the param-
eter items to be checked.
4
  Click the [OK] button.
Illegal polygons will be detected and the fol-
lowing dialog box will appear.
5
  Click the [OK] button.
Only the vertices comprising the illegal poly-
gons will remain selected, the dialog box will 
close and the menu will be exited.