Build – Registration – Fine – Points
Performing Fine Registration of Selected Points
This command is used to perform fine registration of the points present in the selected elements.
 Operating Procedure 
1
  From the element list, select the desired 
elements.
M
emo
•  It is possible to select two or more elements by clicking 
them while holding down the [Shift] or [Ctrl] key.
•  Among the selected elements, the element located first 
in the element list will be used as the basis element for 
registration.
2
  From each selected element, select the 
points to be subjected to fine registra-
tion.
3
  From the [Build] menu, select [Registra-
tion], [Fine] and then click [Points].
The [Build-Registration-Fine-Points] dialog box 
will appear.
•  The selected element will be ready to be dis-
played in all windows. It will be displayed if 
it is not displayed in the active window or the 
windows for which all the elements are set to be 
displayed.
4
 Set the base element, and then click the 
[OK] button.
The program executes fine registration for the 
selected points in the selected elements. It 
then displays a dialog asking whether results 
are satisfactory.
5
  Click the [OK] button.
The menu will be exited.
•  To continue fine registration processing, click the 
[Repeat] button.
M
emo
The [Error Average] and [Sigma] values are indicators of 
the correctness of the registration (the alignment).
In general, the closer to zero they are, the more accurate 