OPTIONAL INSTALLATIONS/SETTINGS
CR-282 
HIGH
-
STABILITY CRYSTAL UNIT
By installing the CR-282, the total frequency stability
of the transceiver will be improved.
Remove the bottom cover as shown on the oppo-
site page.
Remove the 5 screws and 2 flat cables holding the
PLL unit in place.
Remove the existing crystal unit.
Put the CR-282 in the space available as shown in
the diagram.
Adjust the reference frequency at L601 (also R602
and L623 if necessary) using a frequency counter
(60.00000 MHz).
Return the shield case and bottom cover to their
original positions.
CR-282 frequency stability: ±0.5 ppm
(–30°C to +60°C;
–22°F to +140°F)
IF filters
Several IF filters are available for the IC-706MKIIG.
Choose a filter most appropriate to your operating
needs.
Note: After filter installation, specify the installed filter
using initial set mode (items 9, 10). Otherwise, the
installed filter will not function properly.
FL-100 
CW NARROW FILTER
500 Hz/–6 dB
FL-101 
CW NARROW FILTER
250 Hz/–6 dB
FL-103 
SSB WIDE FILTER
2.8 kHz/–6 dB
FL-223 
SSB NARROW FILTER
1.9 kHz/–6 dB
FL-232 
CW/RTTY NARROW FILTER
350 Hz/–6 dB
Remove the top cover as shown on the previous
page.
Install the desired filter as shown in the diagram
below.
• These filters can be installed in either direction.
Replace the top cover.
Filter
CR-282
ribbon
cable
ribbon
cable
L601
R602
L623
Reference freq. c
(60.00000 MHz)
existing 
crystal
PLL unit (bottom)