Motorola DCT1800 User Manual

Page of 53
 
 
Diagnostics B-17 
 
DCT1800 Installation Manual 
d 09: Upstream Modem (STARVUE II Diagnostics) 
This diagnostic shows the status and operating parameters for the STARVUE II RF return.  
Figure B-10  
STARVUE II Diagnostic  
09
STARVUE II DIAGNOSTICS
STATUS:
DISABLED
FREQUENCY:
23.000 MHz
LEVEL:
39
IPPV:
DISABLED
LAST POLL REQ:
170
6-15-2001
20:49:33
LAST POLL ACK:
170
6-15-2001
20:49:33
Table B-11  
STARVUE II Transmitter Fields 
Field Description 
Status 
Indicates the transmitter status with the following variables: 
 
Idle 
 t 
Transmitting 
Frequency 
Indicates the transmitting frequency. 
Level 
Indicates the approximate power value of the STARVUE II transmitter in dBmV. The 
difference between the power value on the diagnostic screen and the actual power of 
the STARVUE II module may be 
±
 5 dBmV. 
IPPV 
Indicates the Interactive Pay-Per-View status with the following variables: 
  ENABLED 
IPPV enabled 
  UNSENT 
−−−−
 
## 
The set-top contains unsent IPPV transactions. The variable 
## is the 
number of unsent transactions. 
  DISABLED 
IPPV disabled 
Last Poll Req. 
Indicates the sequence number of the last poll request received by the set-top. The 
time stamp of the last poll request is displayed under LAST POLL REQ: 
If the set-top has received no poll request, , the sequence number and time stamp 
fields display N/A.  
If the set-top has received a poll request set-top but its system time has not yet 
been initialized, the time stamp field displays NOT AVAILABLE. 
Last Poll Ack. 
Indicates the sequence number of the last poll acknowledge received by the set-top. 
The time stamp of the last poll acknowledge is displayed under LAST POLL ACK.  
If the set-top has received no poll acknowledge, the sequence number and time 
stamp fields display N/A.  
If the set-top has received a poll acknowledge but its system time has not yet been 
initialized, the time stamp field displays NOT AVAILABLE.