57 – Outer barrier is not up and latched and ground 
detect switch did not deactivate (Century and Vista 
only)
58 – Outer barrier is not up and latched and the platform 
is 3” above the ground
59 – Outer barrier is not up after pausing platform travel
60 – The kickout gas springs are worn, replace before 
using
75 – Low voltage detected; must turn off power switch to 
reset LCD
77 – Vehicle secure interlock has not been activated
90 – Position will be set if you keep holding the button 
until it beeps
91 – Position is out of a predetermined acceptable range 
RIÁRRUSRVLWLRQ
92 – Bridge switch is not made, needs adjusting
93 – Inner rollstop occupied switch is not made, position 
needs to be moved or switch should be adjusted
²2XWHUEDUULHULVQRWPDGHÀ[DQGWU\DJDLQ
95 – Outer barrier latch is not made (check for jumper on 
Century and Vista lifts, check latch on Millennium 
lifts)
99 – Controller program is not valid; replace controller 
 Flashing Numbers
Flashing 65 – Unfold button is pressed
Flashing 66 – Fold button is pressed
Flashing 67 – Down button is pressed
Flashing 68 – Up button is pressed
Flashing 69 – Bridge switch is activated
Flashing 70 – Outer barrier latch switch is activated
Flashing 71 – Ground detect switch is activated
Flashing 72 – Outer barrier up switch is activated
Flashing 73 – Inner rollstop up switch is activated
Flashing 74 – Inner rollstop occupied switch is activated
Flashing 76 – Outboard barrier occupied switch is 
activated
Flashing 78 – Threshold tape switch “A” is activated
Flashing 79 – Threshold tape switch “B” is activated
Flashing 80 – Position set button is pressed
LCD Lift Codes
Listed below are codes that the lift controller outputs 
during lift operation. The codes will be displayed on 
an LCD screen located on the lift control board inside 
the pump module.  See the Manual Operating Instruc-
tions in the operator's manual for pump cover removal 
instructions.
Non-Flashing Numbers
01 – Platform stowed
02 – Platform unfolding
03 – Platform unfolding paused
²3ODWIRUPDWÁRRUOHYHO
05 – Platform beginning to lower
06 – Platform lowering (threshold cannot be occupied 
from this point down)
07 – Outer barrier moving to horizontal position
08 – Platform at ground level
09 – Outer barrier moving to vertical position
10 – Platform raising
²3ODWIRUPUDLVLQJSDXVHGDWÁRRU
12 – Platform folding (limited pressure)
13 – Platform folding (full pressure)
14 – Timed fold (cinching lift tite) or (anti-rattle state)
15 – Platform folding stopped
16 – Paused fold
17 – Platform between ground and 3” above ground
18 – Platform above 3”
19 – Outer barrier moving to horizontal postion
²,OOHJDOIXQFWLRQQRWGHÀQHG
29 – Interlock fault not recognized (or has been cleared 
but a motion button is still pressed)
30 – Platform location unknown
31 – Platform location transition state; attempting to 
locate position
35 – Two or more motion buttons are being pressed
36 – The retention belt cannot be buckled while trying 
to fold or unfold
37 – Motion button being pressed is not a valid motion
50 – Outer barrier is not up above inboard barrier 
locked position
51 – Threshold is occupied when platform is 1” or more 
EHORZÁRRUOHYHO
52 – Inner rollstop is not up and locked below inner 
rollstop locked position
53 – Inner rollstop occupied sensor is not activated 
EHWZHHQÁRRUDQGLQQHUUROOVWRSXSSRVLWLRQ
54 – Outer barrier is occupied before it is up
55 – Outer barrier is not latched when above the inner 
rollstop locked position (Millennium only)
56 – Outer barrier is not up and latched and bridge 
switch did not deactivate