Pelco C2429M User Manual

Page of 16
Pelco Installation Manual C2429M (3/01)
15
GENERAL
Environment
In-Ceiling:
Indoor only
Pendant:
Indoor/outdoor
Operating Range
In-Ceiling:
32 to 140°F (0 to 60°C) intermittent operation; 32 to 122°F (0 to 50°C) continuous operation
Pendant
Without Heater:
32 to 140°F (0 to 60°C) absolute maximum operating temperature; 32 to 122°F (0 to 50°C) sustained
maximum operating temperature
With Heater:
(Assumes no wind chill factor; for detailed test conditions, contact Pelco.)
Maximum operating temperature:  140°F (60°C) absolute maximum; 122°F (50°C) sustained maximum
Minimum operating temperature: -60°F (-51.11°C) absolute minimum; minimal icing at -50°F (-45.56°C)
sustained minimum; prevents icing at -40°F (-40°C) sustained minimum; de-ices .1 inch (2.5 mm) within
3 hours after power-up
Dimensions:
See Figure 1
Ratings:
NEMA Type 1–In-ceiling back boxes, all dome drives
NEMA Type 4X–Pendant back boxes
IP 66–Pendant back boxes
Weight
Unit
Back Box
In-ceiling:
2.17 lb (.98 kg)
Pendant Indoor:
4.45 lb (2.02 kg)
Outdoor Pendant:
4.75 lb (2.15 kg)
Dome Drive:
2.6 lb (1.18 kg)
Lower Dome
In-ceiling:
1.6 lb (.73 kg)
In-ceiling w/cage:
Pendant:
1.83 lb (.83 kg)
Pendant w/cage:
(Design and product specifications subject to change without notice.)
Figure 1.  Dimension Drawing
10.1
(25.65)
7.5
(19.05)
9.70
(24.64)
fl 
6.13
(
fl 
15.57)
.125
.060
NOTE:
VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES