30
500
VITC BLANK
0000
0001
BLANK
THRU
For  setting  whether  to  output  the  VITC  signal  to  the  position  set  by  menu
item No.501 (VITC POS-1) and No.502 (VITC POS-2).
0: The VITC signal is not output.
1: The VITC signal is output.
<Note>
This  setting  is  only  effective  for  SD  outputs  (VIDEO  output  and  SD  SDI
output).
501
VITC POS-1
0000
:
0006
:
0010
10L
:
16L
:
20L
For setting the position where the VITC signal is to be inserted.
<Notes>
O
The  same  line  as  that  set  for  menu  item  No.502  (VITC  POS-2)  cannot
be set.
O
This setting is only effective for SD outputs (VIDEO output and SD SDI
output).
502
VITC POS-2
0000
:
0008
:
0010
10L
:
18L
:
20L
For setting the position where the VITC signal is to be inserted.
<Notes>
O
The  same  line  as  that  set  for  menu  item  No.501  (VITC  POS-1)  cannot
be set.
O
This setting is only effective for SD outputs (VIDEO output and SD SDI
output).
503
REGEN
0000
0001
REGEN
PRE
For setting the synchronization method of the internal time code generator.
0: The  time  code  reader  is  synchronized  to  the  time  code  which  is  read
from the tape.
1: The synchronization method can be preset by a front panel operation or
using the remote controller.
504
RUN MODE
0000
0001
REC
FREE
For  setting  the  operation  mode  in  which  the  internal  time  code  generator
advances the time code.
0: The generator advances only during recording.
1: It advances while the power is on regardless of the operation mode.
505
TCG REGEN
0000
0001
0002
TC&UB
TC
UB
For  setting  the  signal  to  be  regenerated  when  the  TCG  (time  code
generator) is in the regeneration mode.
0: Both the time code and user’s bit are regenerated.
1: Only the time code is regenerated.
2: Only the user’s bit is regenerated.
509
PHASE CORR
0000
0001
OFF
ON
For setting whether to control the phase compensation for the LTC output
during playback.
0: The phase compensation is not controlled.
1: The phase compensation is controlled.
508
BINARY GP
0000
0001
0002
0003
0004
0005
0006
0007
000
001
010
011
100
101
110
111
For  setting  the  conditions  under  which  the  user’s  bit  in  the  time  code
generated by TCG is to be used.
0: Not specified (character set is not specified).
1: ISO characters (8-bit character set compliant with ISO646, ISO2022)
2: Unassigned 1 (not defined)
3: Unassigned 2 (not defined)   
4: Unassigned 3 (not defined)
5: Page/line
6: Unassigned 4 (not defined)
7: Unassigned 5 (not defined)
TIME CODE
Item
Setting
No.
Superimposed
display 
No.
Superimposed
display 
Description of setting
The underlining denotes the factory mode.
Setup Menus