Sony SRW-5000 User Manual

Page of 187
176
 Menu List
  App
endi
x
Stop freeze operation
• A “DT picture” is a frozen picture in noiseless DT playback mode. The 
picture freezes in frame mode when the dynamic tracking is performing a 
frame operation. It freezes in field mode when dynamic tracking is not 
performing a frame operation.
• A “non-DT picture” is a frozen picture in shuttle mode. A block pattern 
may appear in a non-DT picture, depending on the circumstances.
Items Relating to the Pulldown Control (Nos. A01 to ...)
980
ALPHA CHANNEL 
LEVEL
white
[black]
For 4:4:4 DUAL LINK output, sets the output level of the 
ALPHA CHANNEL of LINK B output.
white: Output white level.
black: Output black level.
MODE (After)
STOP
TENSION OFF
STDBY OFF
MODE (Before) 
STILL (dynamic tracking on)
DT picture
DT picture
DT picture
CAPSTAN drive (includes shuttling up to 
×
10 normal tape speed)
non-DT picture
non-DT picture
non-DT picture
Reel drive (includes shuttling over 
×
10 normal tape speed)
non-DT picture
non-DT picture
non-DT picture
Item number
Item
Setting
Function
Item number
Item
Setting
Function
A01
PD TIME CODE 
DISPLAY
[off]
on
Sets whether or not to display the pulldown time code on 
the time code display area.
off: Does not display the pulldown time code.
on: Displays the pulldown time code.
A02
PD PRESET 
FRAME MODE
[24F FRAME MODE]
30F FRAME MODE
Selects the time code to be preset. The A frame of the 
pulldown sequence can be preset.
24F FRAME MODE: The 24 frames time code is preset.
30F FRAME MODE: The 30 frames time code is preset.
A03
FC 
SUPERIMPOSED 
CHARACTER
[off]
on
Specifies whether or not to superimpose time data and 
operating status information on the signal output from the 
FORMAT CONV. OUT connector.
off: No information is superimposed.
on: Information is superimposed.
A04
PD DF/NDF 
SELECT
[drop frame]
non-drop frame
auto
Selects the running mode for the pulldown time code to be 
preset.
drop frame: Drop frame mode
non-drop frame: Non-drop frame mode
auto: The unit switches the running mode (DF/NDF) 
automatically according to the frame frequency of the 
unit. When the frame frequency is 23.98 Hz, the unit 
switches to the drop frame mode and switches to the 
non-drop frame mode when it is 24 Hz.