Sony SRW-5000 User Manual

Page of 187
60
4-3 TC Menu
  C
h
ap
te
r 4
  
M
e
nu 
Se
tt
in
g
s
To pause the current time
Press the [F4] (TIMER HOLD) button.
The time is paused only while the button is held down.
4-3-2 Setting the Time Code Reader 
(TCR SEL)
Press the [F5] (TCR SEL) button to select the time code to 
be read by the time code reader during playback.
VITC:  Reads VITC.
auto:  Reads VITC when the playback speed is ±1/2 times 
normal speed or less, and LTC when it is greater than 
±1/2 times normal speed.
LTC:  Reads LTC.
Depending on the time code recorded on a tape, VITC or 
LTC appears on the display.
Time codes that are read by the time code reader or played 
back are output from the TIME CODE OUT connector.
4-3-3 Setting the Time Code 
Generator (TCG SOURCE/MODE)
There are two ways to record time codes on the VTR. One 
way is to record the output of the VTR’s internal time code 
generator. The other is to directly record time codes that 
are input from an external time code generator.
The output from the internal time code generator can either 
be set to a specified initial value, or synchronized with an 
external time code generator.
The internal time code generator time code settings are 
made with the [F6] (REGENE SOURCE)/[F7]  (TCG 
MODE) buttons. Menu selections and settings are shown 
in the following table.
Regenerated signals are selected using the VTR SETUP 
menu item 608 “TCG/UBG REGENE MODE setting”.
To check the running of the internal time code 
generator
Press the INPUT CHECK button.
4-3-4 Selecting the Time Code 
Running Mode (RUN MODE)
Press the [F8] (RUN MODE) button to select the time code 
running mode.
free:  The time code advances when the power is on 
regardless of the VTR’s operation mode.
rec:  The time code advances only during recording.
Note
TCG
[F6] 
(REGENE 
SOURCE)
[F7] (TCG 
MODE)
Setting
Internal TCG 
(Preset)
prst
Time codes 
can be freely 
set using the 
internal time 
code generator
Internal TCG 
(Regenerate)
int-LTC
regene
Lock to the 
time data 
recorded on 
the time code 
tracks
int-VITC
regene
Lock to the 
time data 
recorded as 
video AUX data 
on the tape
ext-LTC
regene
Lock to the 
time data on 
the TIME 
CODE IN 
connector
SDI-V
regene
Lock to the 
VITC time data 
in the video 
signal from the 
HD SDI INPUT 
A/B connector
SDI-L
regene
Lock to the LTC 
time data in the 
video signal 
from the HD 
SDI INPUT A/B 
connector
auto
“int-LTC/
regene” is set 
in assemble or 
insert mode 
and “prst” is set 
in other modes
Note
Menu