Troubleshooting
C
hap
te
6
   M
a
in
tena
nce and
 T
roub
le
sho
o
ting
Troubleshooting
If an alarm message appears on the monitor screen, or if 
the unit appears to be malfunctioning, please check the 
following before contacting your Sony dealer.
Tape problems
Symptom
Cause
Remedy
Recording is not 
possible.
The cassette’s REC/SAVE switch is set 
to SAVE.
Set the REC/SAVE switch to REC, or use another cassette.
The unit’s tape 
transport control 
buttons (PLAY, F FWD, 
REW, etc.) do not 
work.
The REMOTE indicator in the display 
section is lit and the LOCAL ENABLE 
menu item is set to STOP & EJECT or 
ALL DISABLE.
Set the LOCAL/REMOTE switch to LOCAL to turn the 
REMOTE indicator off, or change the setting of the LOCAL 
ENABLE menu item 
 to ALL ENABLE. 
No cassette is loaded.
Insert a cassette 
.
The NO EDIT indicator 
on the front panel lights 
up.
The audio recording mode selected on 
this unit does not coincides with that of 
the loaded tape.
• When your current purpose is editing, set the LOCAL/
REMOTE switch to LOCAL to turn the REMOTE indicator 
off and set the unit for the same audio recording mode as 
with the tape using the REC MODE menu item 
, then set the switch to REMOTE to light the REMOTE 
indicator again.
• When your current purpose is recording, you can use the 
tape currently loaded in the unit.
The recording format of the currently 
loaded tape is DV or DVCPRO.
Replace the tape with one recorded in the DVCAM format.
The recording format selected on this 
unit is DV (SP).
Select the DVCAM format.
Time data problems
Symptom
Cause
Remedy
Cannot freely set the 
initial time data value.
The TC MODE menu item is set to EXT 
REGEN.
Change the setting of the TC MODE menu item 
 to INT PRESET.
CNT is selected as the time data type 
to be displayed (the COUNTER time 
data type indicator is lit).
Press the COUNTER SELECT button to make the TC or U-
BIT time data type indicator light up (the CNT value cannot 
be set freely).
The REMOTE indicator in the display 
section is lit and the LOCAL ENABLE 
menu item is set to STOP & EJECT or 
ALL DISABLE.
Set the LOCAL/REMOTE switch to LOCAL to turn the 
REMOTE indicator off or change the setting of the LOCAL 
ENABLE menu item 
 to ALL ENABLE.
The tape is running, 
but the time data is not 
shown in the time 
counter display.
The MENU button or TC PRESET 
button in the menu control section has 
been pressed.
Press the button once again to exit the menu control mode, 
time code preset mode, or digital hours meter display mode. 
(In either of the menu control mode and time code preset 
mode, the time data is not shown in the time counter display.)
The U-BIT time data type indicator is lit. Press the COUNTER SELECT button to make the 
COUNTER or TC time data type indicator light up.
Input problem
Symptom
Cause
Remedy
It is not possible to 
record an SDTI (QSDI) 
signal.
No SDTI signal is input to the unit, or 
the SDTI format has not been selected.
Connect an SDTI signal to the SDI/SDTI (QSDI) IN 
connector, or set the DIGITAL OUTPUT menu item 
 to SDTI.