Sony 1500AP User Manual

Page of 125
82
Displaying Supplementary Status Information
Ch
ap
te
r 4
  
 M
e
nu
 S
e
tti
n
gs
Displaying 
Supplementary Status 
Information
When you set the SUB STATUS menu item (see page 67) 
to other than OFF, you can view supplementary status 
information on the monitor screen below the operating 
mode display area.
The following items of supplementary status information 
are displayed depending on the setting of the SUB 
STATUS menu item.
The following tables show the on-screen indications of 
supplementary information and their meaning.
In each table, the indications given in brackets such as 
[ASM] are the indications displayed when the SUB 
STATUS menu item is set to ALL.
For the display format when ALL is selected, see the next 
section.
Setting of SUB 
STATUS menu item
Items of supplementary 
information displayed
EDIT PRESET
Editing mode settings made on the 
editing control unit
TC MODE
Operating mode of the internal time 
code generator
REMAIN
Remaining capacity of the tape
AUDIO MIXING
Setting for input audio mixing
ALL
All of the above items
When the SUB STATUS menu item is set to EDIT 
PRESET:
On-screen 
indication
Meaning
ASM
[ASM]
Assemble editing mode
INS V A1234 TC
[V1234T]
INS: Insert editing mode
V A1234 TC: Channels or signals 
selected for insert editing
V: Video
A1234: Audio 1, 2, 3, 4
TC: Time code
T C R
P L A Y
0 0 : 0 4
4 7
.
0 7
L O C K
.
I N
V
A 1
3 4
2
T C
S
Supplementary status information
When the SUB STATUS menu item is set to TC MODE:
On-screen 
indication
Meaning
INT PRST FREE
[IP F]
The internal time code generator is 
operating in FREE RUN mode.
INT PRST REC
[IP R]
The internal time code generator is 
operating in REC RUN mode.
INT REGEN-T&U
[IRTU]
The internal time code generator is in 
synchronization with the playback 
time code (LTC) read from tape.
EXT LTC-T&U
[ELTU]
The internal time code generator is in 
synchronization with the external time 
code (LTC) input to the unit and is 
generating the same time code value 
and user bit value as those of the 
external time code (regeneration).
EXT VITC-T&U
[EVTU]
The internal time code generator is in 
synchronization with VITC present in 
the external video signal input to the 
unit and is generating the same time 
code value and user bit value as 
those of the external time code 
(regeneration).
EXT QSDI-T&U
[EQTU]
The internal time code generator is in 
synchronization with the external time 
code input to the unit via the SDTI 
(QSDI) interface and is generating the 
same time code value and user bit 
value as those of the external time 
code (regeneration).
EXT QSDI. V-T&U
[EQTU]
The internal time code generator is in 
synchronization with the external 
VITC input to the unit via the SDTI 
(QSDI) interface and is generating the 
same time code value and user bit 
value as those of the external time 
code (regeneration).
EXT DVIN-T&U
[EDTU]
The internal time code generator is in 
synchronization with the external time 
code input to the unit via the i.LINK 
(i.DV IN) interface and is generating 
the same time code value and user bit 
value as those of the external time 
code (regeneration).
EXT DVIN. V-T&U
[EDTU]
The internal time code generator is in 
synchronization with the external 
VITC input to the unit via the i.LINK 
(i.DV IN) interface and is generating 
the same time code value and user bit 
value as those of the external time 
code (regeneration).
When the SUB STATUS menu item is set to REMAIN:
On-screen 
indication
Meaning
REMAIN 184 min
Remaining capacity of the tape in 
minutes.
When the remaining capacity has not 
been calculated, “REMAIN --- min” 
appears.