Operation
309967C
11
Operation
Pressure Relief Procedure
1. Shut off the air to the pump.
2. Bleed off the air pressure by closing the air regulator 
(self–relieving type), or closing the bleed–type mas-
ter air valve installed upstream of the air regulator, 
or disconnecting the air supply hose at the 
quick–disconnect.
3. Hold a metal part of the gun or valve firmly to the 
side of a grounded metal waster container and trig-
ger to relieve fluid pressure.
 Start–up: Single or Multiple Pump Systems
1. Close the air regulators and bleed–type master air 
valves to all but one pump.
2. Open the master air valve from the compressor.
3. For the pump which is connected, trigger the dis-
pensing valve into a grounded metal waste con-
tainer, making firm metal–to–metal contact between 
the container and valve. Open the bleed–type mas-
ter air valve, and open the pump air regulator slowly 
until the pump is running. When the pump is primed 
and all air has been pushed out of the lines, release 
the trigger.
4. If you have more than one pump, repeat this proce-
dure for each pump.
5. Set the air pressure to each pump at the lowest 
pressure needed to get the desired results.
6. Read and follow the instructions supplied with each 
component in the system.
7. When shutting off the system, always follow the 
Pressure Relief Procedure.
NOTE: When the pump is primed, and with suffi-
cient air supplied, the pump starts when the dis-
pensing valve is opened and shuts off when it is 
closed.
NOTE: A pump runaway valve can be installed on 
the air line to automatically shut off the pump if it 
starts to run too fast.
NOTE:  Never allow the pump to run dry of the fluid 
being pumped. A dry pump will quickly accelerate 
to a high speed, possibly damaging itself. If the 
pump accelerates quickly or is running too fast, 
stop it immediately and check the fluid supply. If the 
supply container is empty and air has been 
pumped into the lines, prime the pump and lines 
with fluid, or flush it and leave it filled with a com-
patible solvent. Be sure to eliminate all air from the 
fluid system
The maximum working pressure of each pump in your 
system may not be the same. To reduce the risk of 
over–pressurizing any part of your system, be sure you 
know the maximum working pressure rating of each 
pump and its connected components. Never exceed 
the maximum working pressure of the lowest rated 
component connected to a particular pump.
To determine the fluid output pressure using the air 
regulator reading, multiply the ratio of the pump by the 
air pressure shown on the regulator gauge. For exam-
ple:
 50:(1) ratio x 100 psi air = 5000 psi fluid output
 50:(1) ratio x 0.7 MPa air = 35 MPa fluid output
 50:(1) ratio x 7 bar air = 350 bar fluid output
Limit the air to the pump so that no air line or fluid line 
component or accessory is overpressurized.