Shindaiwa GP344 Owner's Manual

Page of 24
8
IMPORTANT!
The primer system only pushes fuel 
through the carburetor. Repeatedly 
pressing the primer bulb will not flood 
the engine with fuel.
CAUTION!
Do not pull the recoil starter to the 
end of the rope travel. Pulling the 
recoil starter to the end of the rope 
travel can damage the starter.
Place suction intake and strainer 
1. 
in the water to be pumped prior to 
starting engine. 
Set throttle control lever to the half 
2. 
open position. See Figure 3.
Press the primer bulb until fuel can 
3. 
be seen flowing in the transparent 
return tube. See Figure 4.
Starting the Engine
WARNING!
Do not run engine in an 
enclosed area. Exhaust gas con-
tains carbon monoxide, an odorless 
and deadly poison.
IMPORTANT!
If the engine fails to start after several 
attempts with the choke in the closed 
position, the engine may be flooded 
with fuel. If flooding is suspected, move 
the choke lever to the open position 
and repeatedly pull the recoil starter 
to remove excess fuel and start the 
engine. If the engine still fails to start, 
refer to the troubleshooting section of 
this manual.
Set the choke lever to the CLOSED 
4. 
position if the engine is cold.
While holding the pump handle 
5. 
firmly with your left hand, use your 
other hand to slowly pull the recoil 
starter handle until resistance is 
felt, then pull quickly to start the 
engine. See Figure 6
When the engine starts, slowly 
6. 
move the choke lever to the 
"OPEN" position. See Figure 7. (If 
the engine stops after the initial 
start, close the choke and restart.)
Figure 4
Figure 3
Figure 6
Open
Primer bulb
Return tube
Figure 5
Close
Figure 7
If the engine does not start
Repeat the appropriate procedures for starting a warm or cold engine.
1. 
If the engine fails to start, follow the procedures in “Starting a Flooded 
2. 
Engine”.
IMPORTANT!.
Do not start or run the pump without 
priming the pump with water. Serious 
damage to the pump seals will occur 
when the pump is run dry.
When the engine starts, gradu-
7. 
ally move the throttle control 
lever back to the idle position 
(counterclockwise).
After the engine starts, allow the 
8. 
engine to warm up at idle 2 or 3 
minutes before operating the unit.
Place throttle lever (D) in half throt-
9. 
tle position until pump begins to 
pump water. Then move lever to full 
throttle.
Starting A Flooded Engine
Open the choke, put the throttle trigger in the full throttle position, then clear excess fuel from the combustion chamber by 
1. 
cranking the engine several times.
If the engine still fails to start or fire, refer to the troubleshooting flow chart at the end of this manual.
2. 
D