 Platform Scale 9K0U    Operator Guide
   Symptom
Probable Cause
Recommendation
Blank Screen
1.   Sleep Mode
Touch the ZeroEnter, or CE/C key, or 
touch the weight platter.
2.   Scale power supply 
unplugged
Check power supply is firmly connected 
at each end.  Remove plug from wall 
outlet, wait 10 seconds; reconnect.
3.   Rate card not firmly 
in slot/inserted back-
wards
Disconnect power, remove card, rub a 
pencil eraser over the gold contacts to 
clean them, insert card as illustrated in 
Chapter 6, reconnect power.
Scale does not return to 
Zero
Interference with scale 
platter
Check the area around the scale to 
ensure that nothing is touching the 
scale platter by either leaning against 
it or pressing up on the platter. Press 
Zero key.
Scale displays Zero 
weight only
Out of calibration or me-
chanical interference
Check for foreign matter under scale 
platter.  Call the Diagnostic Center.
Scale display does not 
reach weight capacity
Platter incorrectly 
seated or mechanical 
interference
Ensure platter is correctly seated.  
Check for foreign matter under scale 
platter.
Inconsistent weights
1.   Air currents moving 
across platter
Move scale to another location.
2.   Platter or item being 
weighed touching 
another object
Clear the area around the scale.
3.   Vibrations affecting 
scale
Turn on vibration filter.