Invacare X-Terminator BB User Manual

Page of 76
SECTION 7—FOOTREST/ ANTI-TIPPER
63
Installing/Adjusting Optional Clamp on Raised Footrest
NOTE: For this procedure, refer to FIGURE 7.2.
NOTE: This procedure is for Terminator Everyday (ED) wheelchairs ONLY. 
Installing
1. Install the two half clamps onto either 
side of the wheelchair frame 
approximately 2‐inches above existing 
footrest with two provided allen 
screws.
2. Repeat for the opposite side of the 
wheelchair.
3. Slide the clamp on raised footrest into 
the half clamps to the desired height.
4. Securely tighten the four allen screws.
Adjusting
1. Loosen the four allen screws.
2. Adjust clamp on raised footrest to the desired height.
3. Securely tighten the four allen screws.
Replacing/Adjusting Optional A4 Footrest
NOTE: For this procedure, refer to FIGURE 7.3.
NOTE: This procedure is for Terminator Everyday (ED) wheelchairs Only. 
Replacing the Footrest
1. Loosen, but DO NOT remove the two allen screws that secure the footrest to the 
wheelchair frame.
2. Slide the existing footrest tubes out of the wheelchair frame and install new footrest 
by reversing this step.
3. Position the new footrest to a determined height.
4. Tighten the two allen screws that secure the footrest to the wheelchair frame.
5. Adjust the footplate to the desired position. Refer to Adjusting Footplate Angle on 
Allen 
Screws
Wheelchair Frame
Outside 
Footrest 
Hoop
Half Clamp
Raised 
Footrest