Spectralink 8002 User Manual

Page of 99
Troubleshooting 
PN: 1725-36034-001_B.doc 
89 
Handset Status Messages 
SpectraLink Wireless Telephone status messages provide information 
about the SpectraLink 8002 Wireless Telephone’s communication with 
the AP and host telephone system. The following table summarizes, 
in alphabetical order, the status messages. 
Message 
Description 
Action 
Address Mismatch 
Handset software download files 
are incorrect or corrupted. 
Download new software from the 
SpectraLink website per Software 
Maintenance
ASSERT xxx c 
Line yyy 
The handset has detected a fault 
from which it cannot recover. 
Record the error code  so it can be 
reported.  
Turn the handset off then on again.  
If error persists, try registering a different 
handset to this telephone port. 
If error still persists, contact Polycom 
Technical Support and report the error. 
Assoc Failed 
xxxxxxxxxxxx 
x…x = AP MAC address.
Handset association was refused 
by AP; displays MAC of failing AP. 
Check handset and AP security settings. 
Ensure AP is configured per Configuration 
Note.  
Try another AP. 
Assoc Timeout 
xxxxxxxxxxxx 
x…x = AP MAC address.
Handset did not receive association 
response from AP; displays MAC of 
failing AP. 
Check handset and AP security settings. 
Ensure AP is configured per Configuration 
Note.  
Try another AP. 
Auth Failed 
xxxxxxxxxxxx 
x…x = AP MAC address.
Handset authentication was refused 
by AP; displays MAC of failing AP. 
Check handset and AP security settings. 
Ensure AP is configured per Configuration 
Note.  
Try another AP. 
Auth Timeout 
xxxxxxxxxxxx 
x…x = AP MAC address.
Handset did not receive 
authentication response from AP; 
displays MAC of failing AP. 
Check handset and AP security settings. 
Ensure AP is configured per Configuration 
Note.  
Try another AP. 
Bad Code Type xx 
Expected Code 
Type yy 
xx, yy = software license types. 
Handset software does not match 
current handset license selection. 
Check current handset license selection, 
slnk.cfg.cfg file contents. If necessary 
obtain new software per Software 
Maintenance
Bad Config 
Some needed configuration 
parameter has not been set. 
Check all required handset configuration 
parameters for valid settings. 
Bad ESSID 
The handset is configured for “static 
ESSID” (as opposed to “Learn 
once” or “Learn always”), and no 
ESS ID has been entered. 
Enter an ESSID in the configuration 
settings or change to one of the “Learn” 
modes. 
VoIPon    www.voipon.co.uk    sales@voipon.co.uk    Tel: +44 (0)1245 808195     Fax: +44 (0)1245 808299