Sony FS-2570 User Manual

Page of 222
11  NBDP TRANSMITTING, RECEIVING 
11-9 
When the predetermined time comes, the NBDP Terminal Unit automatically sends or 
receives the message. The results of timer operation are displayed as either OK or NG 
(No Good) on the Timer Operation List. 
*1
 2
*3
*OP4
*OP5
OK
OK
OK
NG
Timer Operation List
 
Timer operation list 
 
11.6.2 Stopping timer operation 
1.  Press the function key [F3]. 
2.  Press the [7] key. 
3.  Choose the operation (name) which has an asterisk attached to it and then press the 
[Enter] key. Remove all asterisks to cancel all timer programs. 
 
 
11.7 Scanning 
The radio equipment scans a group of operator-selected frequencies (channels), and 
stops scanning when an signal is received. For registering scan group, see paragraph 9.5. 
 
1.  Press the function key [F3] and then the [5] key to show the Scanning Group List on 
your screen. 
You can confirm the scan channel by pressing the [
] or [
] key while pressing the [Shift] 
key. 
*
1
 2
 3
Scanning Group List
 
Scanning group list 
2.  Choose a scan group and press the [Enter] key. 
3.  The scanning starts and the indication "Scan" appears in reverse video. Further, the 
name of the scan group appears in the Station Name field. 
2002-09-08 2:01:46 UTC     Caps-Eng
1:File 2:Edit 3:Operate 4:Window 5:Station 6:System 7:WRU 8:HR 9:Over 10:Break
Station Name    :  SAITO-1                   
Scan           HT
  
 
 
Frequency (T/R) :  8344.00 / 8705.00(kHz)  Comm Mode : Auto
Comm Status     :  Connect Send Lock Error  
Sending Volume  :  100(%)   ARQ Error : 0   ARQ Time : 0(sec)
 
Communication status display 
4.  To stop scanning, press the function key [F3] and then the [5] key. “Scan” appears in 
normal video on the communication status display. 