Panasonic MN101C77C User Manual

Page of 544
XI - 11
Chapter 11    Serial Interface 0, 1
Control Registers
„Serial Interface 0 Mode Register 3 (SC0MD3)
All flags are only for reading.
Figure 11-2-6    Serial Interface 0 Mode Register 3 (SC0MD3 : x'03F95', R)
0
1
2
4
5
6
7
3
(At reset : 0 0 0 0 0 0 0 0 )
SC0MD3
SC0ERE
SC0ORE
SC0PEK
SC0FEF
SC0REMP
SC0TEMP
SC0RBSY
SC0TBSY
0
1
No error
Error monitor flag
Error
SC0ERE
0
1
No error
Overrun error detection
Error
SC0ORE
0
1
No error
Parity error detection
Error
SC0PEK
0
1
No error
Framing error detection
Error
SC0FEF
0
1
Empty
Receive buffer empty flag
Full
SC0REMP
0
1
Empty
Transfer buffer empty flag
Full
SC0TEMP
0
1
Other use
Serial bus status
Serial reception in progress
SC0RBSY
0
1
Other use
Serial bus status
Serial transmission in progress
SC0TBSY