Panasonic 700 User Guide

Page of 394
Appendix B. CPC-AII/B 8.0 Feature Update
Section 700-Operation
Page B-14
DBS Manual - Revised April 2000
DBS-2.3/9.2-700
Incoming Calls
• You cannot program both devices to ring simultaneously.
• The “*71” code will not work if the other device is in use.
• The “*71” code will not work if FF3 (ExtPort)# 51# is set to “0”.
• If set to “Analog port RING”, the large-display phone will work like an 
SLT/OPX (no page announcements, no voice calls from other 
extensions, etc.).
• If the phone is in CF/DND (Call-Forward or Do Not Disturb), the phone 
will remain in CF/DND even if the ringing device is changed via the 
*71 code.
• The incoming ring pattern for the analog device is the same as for the 
digital key telephone (determined by the Extension Ring Pattern in FF3 
(ExtPort)# 39# (0-9)#). If this address is set to “0” (determined by CO), 
the analog device will automatically default to “1 second ON, 3 seconds 
OFF.”
Ring Patterns Not Applicable to Analog Device. The following ring 
pattern addresses will not affect the analog device:
Analog Transfer Ring Pattern FF1  2#  1#  31#  (0-6)#
SLT DISA Ring Pattern
FF1  2#  1#  34#  (0 or 1)#
Inbound Ring Pattern
FF2  (Trunk)#  17#  (0-9)#
Flash Interaction. Any disconnect signal sent to the analog port must be 
greater than the SLT Flash Control; otherwise the disconnect signal will be 
interpreted as a flash and the call will be placed on hold.
Programming Addresses That Affect the Analog Device. The following 
addresses will control the analog device, but will not affect the digital key 
telephone:
AEC Disconnect Duration
FF1  2#  1#  35#  (0-15)#
SLT Flash Control
FF1  2#  1#  11#  (0 or 1)#
SLT Onhook Flash Timer
FF1  3#  14#  (0-6)#
AEC Disconnect
FF3  (ExtPort)#  46#  (0 
or 1)#
Analog Port on Large-Display Phone 
FF3  (ExtPort)#  51#  (0 
or 1)#
Data Security on Analog Port 
FF3  (ExtPort)#  52#  (0 
or 1)#