Panasonic 700 User Guide

Page of 394
Section 700 - Operation
Chapter 3. System Features
DBS-2.3/9.2-700
DBS Manual - Revised April 2000
  Page 3-9
• FF1 (System): Auto Night2 Mode Start Timer
Considerations
• If all auto modes are set, the starting times must differ by at least one hour.
• When one auto mode is turned on, the mode cannot be reset by the NIGHT 
key until 3 minutes after the auto mode is activated. (When all auto modes 
are set, the mode keys cannot be used.)
• If mode keys are not set, the access codes #520 (DAY/NIGHT1/NIGHT2 
toggle), #521 (DAY), #522 (Night1) or #523 (Night2) can be used instead.
Auto Set Relocation
(CPC-AII and CPC-B Version 3.1 or higher)
Description
Auto Set Relocation can be used to relocate the program settings of one 
extension to another extension. 
Auto Set Relocation is commonly used when extension users want to trade 
work areas. For example, if Extensions “A” and “B” are going to switch 
office locations, Auto Set Relocation enables them to switch telephone 
settings without re-programming.
Operation
Before a phone can be relocated, it must be assigned an Auto Set Relocation 
code. See “Related Programming” for the program address used to set up the 
Auto Set Relocation Code.
The following example illustrates how the program settings for extensions 
200 and 300 could be switched. 
To Transfer Extension Settings from 200 to 300:
1.  At extension 300, pick up the handset.
2. Press 
“#10.”
3.  Dial extension number 200.