Panasonic 700 User Guide

Page of 394
Section 700 - Operation
Chapter 3. System Features
DBS-2.3/9.2-700
DBS Manual - Revised April 2000
  Page 3-53
Figure 2-3. SMDR Format for CPC-A and CPC-B Versions Prior to 3.1
Related Programming
• FF1 (System): Parity Check
• FF1 (System): Odd/Even Parity
• FF1 (System): Baud Rate
• FF1 (System): Stop Bit Length
• FF1 (System): Data Length
• FF1 (System): Serial Port Flow Control (X On/ X Off)
• FF1 (System): SMDR Display Start Timer for CO Calls
• FF1 (System): SMDR Printing Mode 1: Outbound and Inbound
• FF1 (System): SMDR Printing Mode 2: Long Distance and Local Calls
• FF1 (System): SMDR Printing Mode 3: Header Title
• FF3 (Extension) Station Message Detail Recorder (SMDR) Report
Hardware Requirements
• A printer or external call accounting system is required to receive SMDR 
data.
 0         1         2         3         4         5         6         7
 01234567890123456789012345678901234567890123456789012345678901234567890
 
    1     2      3   4   5             6               7       8    
  MM DD HH:MM H:MM.X C  NN     DDDDD-DDD-DDD-DDDD     NNN  AAAAAAAAAA
1=Date
  MM=month
  DD=day
2=Call start time
  HH=hour
  MM=minute
3=Call duration
  H=hour (0-9)
  MM=minutes
  X=1/10th of a minute (0-9)
4=Call condition
  I=incoming
  i=DISA incoming
  O=DISA outgoing
  D=Call longer than 10 hours
5=Trunk number
  NN=number (01-64)
6=Dialed digits
  DD=digits 0-9 or symbols * or
 #
  (See the Note following item 8.)
7=Extension number or DISA number
  10-73, 100-699=extensions
  
#
01-
#
64=DISA numbers
8=Account code
  A=digits 0-9 or symbols * or 
#
  
Note: The * symbol appears as a       
greater-than sign (>) on the SMDR
printout; the # symbol appears as a 
less-than sign (<).