Oregon Scientific RAR681 User Manual

Page of 2
Wireless Indoor / Outdoor Thermometer 
with Digital Clock
Model: RAR681
USER MANUAL
INTRODUCTION
Thank you for selecting the Oregon Scientific™ Wireless 
Indoor  /  Outdoor  Thermometer  with  Digital  Clock 
(RAR681). The main unit can support up to 3 sensors. 
To  purchase  additional  sensors,  please  contact  your 
local retailer. 
NOTE    Please  keep  this  manual  handy  as  you  use 
your  new  product.  It  contains  practical  step-by-step 
instructions,  as  well  as  technical  specifications  and 
warnings you should know about.
OVERVIEW
FRONT VIEW
1.  Sensor low battery warning 
2.   Outdoor temperature trend icon 
3.   Hi / lo alarm is displayed 
4.   Ice warning is active
5.   Channel number and sensor reception status 
6.   Maximum / minimum outdoor temperature reading 
7.   Outdoor temperature reading
8.  Alarm is set 
9.  Alarm is displayed
10. 12-hour clock
11. Indoor temperature display icon 
12. Indoor temperature trend icon 
13. Main unit low battery warning 
14. Maximum / minimum indoor temperature reading 
15. Indoor temperature reading
16. Time, alarm and date
BACK VIEW
1.  TEMP  HI  /  LO 
  :  Change  settings  or  enable  / 
disable hi or lo temperature alarm for channel 1
2.  
  / 
:  Increase  /  decrease  setting;  activate  / 
deactivate clock reception signal 
3.  CHANNEL: Switch remote sensor display 
4.  MODE: Change settings / display 
5.  ALARM: View alarm status; set alarm
6.  Battery compartment
7.  MEM:  View  current,  maximum  and  minimum 
temperature
8.  °C / °F: Select temperature unit °C / °F
9.  RESET: Reset unit to default settings
REMOTE SENSOR (THN122N)
 
1. LED status indicator:  
1.  Wall mount hole
  Blinks red during data 
2.  RESET hole 
  transmission 
3.  CHANNEL switch
2. Ventilation duct 
4.  Battery compartment 
GETTING STARTED
POWER
Insert  batteries  before  first  use,  matching  the  polarity 
(+ and -).
NOTE  Install batteries in the remote sensor before the 
main unit. Press RESET after each battery change. Do 
not  use  rechargeable  batteries.  We  recommend  that 
you  use  alkaline  batteries  with  this  product  for  longer 
usage  and  lithium  batteries  in  temperatures  below 
freezing.
  shows when batteries are low.
UNIT 
  LOCATION
Main 
Indoor temperature area
Remote 
Outdoor temperature area
REMOTE SENSOR
The sensor collects temperature readings approx. every 
40 seconds and sends them to the main unit. The main 
unit can collect data from up to 3 sensors.
To set up the sensor:
1.  Remove the screws from the battery door.
2.  Insert the batteries, matching the polarity  (+ / -).
3.  Select  a  channel.  Make  sure  you  use  a  different 
channel for each sensor.
4.  Place the sensor near the main unit. Press RESET 
on the sensor. 
5.  Simultaneously press CHANNEL and MEM on the 
main  unit  to  initiate  signal  sending  between  the 
sensor and main unit.
6.  Close the battery door and secure the screws.
7.  Place the sensor in the desired location using the 
table stand or wall mount.
For best results:
  Place  the  sensor  out  of  direct  sunlight  and 
moisture. 
  Do not place the sensor more than 30 meters (100 
feet) from the main (indoor) unit.
  Position the sensor so that it faces the main (indoor) 
unit, minimizing obstructions such as doors, walls, 
and furniture.
  Place the sensor in a location with a clear view to 
the sky, away from metallic or electronic objects.
  Position the sensor close to the main unit during cold 
winter months as below-freezing temperatures may 
affect battery performance and signal transmission. 
The transmission range may vary depending on many 
factors.  You  may  need  to  experiment  with  various 
locations to get the best results.
Standard  Alkaline  batteries  contain  significant 
amounts  of  water.  Because  of  this  they  will  freeze 
in  low  temperatures  of  approximately  -12°C  (10°F). 
Disposable  Lithium  batteries  have  a  much  lower 
threshold  for  temperature  with  an  estimated  freezing 
range of below -40°C (-40°F).
Wireless ranges can be impacted by a variety of factors 
such  as  extremely  cold  temperatures.  Extreme  cold 
may temporarily reduce the effective range between the 
sensor and the base station. If the unit’s performance 
fails due to low temperature, the unit will resume proper 
functioning  as  the  temperature  rises  to  within  the 
normal temperature range (i.e. no permanent damage 
will occur to the unit due to low temperatures). 
SENSOR DATA TRANSMISSION
Data is sent from the sensor(s) every 40 seconds. The 
reception icon in the outdoor temperature area shows 
the status.
            ICON 
DESCRIPTION
   
Main unit is searching
   
for the sensor(s)
   
A channel has been found
   
Sensor 1 is sending data
 
             and - -.- 
The sensor cannot be found. 
            (Outdoor  
Search for the sensor or 
temperature area) 
check batteries
To search for a sensor: 
Simultaneously,  press  and  hold  MEM  and  CHANNEL 
for 2 seconds.
NOTE  If the sensor is still not found, check the batteries, 
obstructions, and remote unit location.
CLOCK 
To set the clock:
1.  Press and hold MODE for 2 seconds.
2.  Press 
 and 
 to change the settings.
3.  Press MODE to confirm.
4.  The setting sequence is: 12 / 24 hour format, hour, 
minute, year, date / month format, month, date, and 
display language.
NOTE  The  language  options  are  (E)  English,  (F) 
French, (D) German, (I) Italian and (S) Spanish.
To switch the clock display:
Press MODE to toggle between:
  Clock with seconds 
  Clock with day 
  Calendar
ALARM
To set the alarm:
1.  Press ALARM to view the alarm. 
 will show on 
the display.
2.  Press and hold ALARM for 2 seconds.
3.  Press 
 or 
 to change the hour / minute settings.
4.  Press ALARM to confirm.
To activate or deactivate the alarm:
Press ALARM when in the alarm display. 
 appears 
when the alarm is set.
To silence the alarm and reset it for the next day:
Press ALARM.
1
11
12
14
15
16
13
2
3
4
5
6
7
8
9
10
2
1
7
8
9
3
4
5
6
1
2
1
2
3
4
RAR681_EN.indd   1
2005.12.9   2:21:22 PM