Oregon Scientific THWR800 User Manual

Page of 2
EN
Water Thermo Sensor 
Model:  THWR800 / THWR800A
USER MANUAL
FRONT VIEW
1
1.  LED indicator
BACK VIEW
1.  Tubular casing
2.  RESET button
3.  String hole
SCREEN DISPLAY
1
2
3
1.  Channel indicator 
2.  Low battery indicator
3.  Temperature display
INTRODUCTION
This  sensor  is  compatible  with  various  weather  station 
products that carry this logo 
.
GETTING STARTED
The  battery  compartment  resides  in  the  tubular  casing, 
and the switches for selecting channels and temperature 
unit are located on the inside of the main lid.
1.  Twist the main lid to   (unlock position), then pull it 
apart from the tubular casing.
2.  Remove  the  battery  compartment  lid  and  insert  2 
x  UM-3  /  AA  1.5V  batteries,  matching  the  polarity. 
Replace the battery compartment lid.
1
2
4
3
 NOTE  Standard Alkaline batteries contain a significant 
amount  of  water.  Because  of  this  they  will  freeze  in  low 
temperatures  of  approximately  -12°C  (10°F).  Disposable 
Lithium  batteries  have  a  much  lower  threshold  for 
temperature with an estimated freezing range of below 
-40°C (-40°F).
 IMPORTANT    Do not use rechargeable batteries.
  WARNING    While  you  may  use  Lithium  batteries  to 
power the sensor, and although the sensor can withstand 
low  temperatures,  it  is  not  recommended  to  use  it  in 
temperatures  below  0°C  (32°F).  Placing  the  sensor  in 
frozen water may damage the unit.
3.  The diagram below is the inside of the main lid. Select 
a channel from Channel switch (1). If using more than 
one remote unit, select a different channel number for 
each  unit.    Select  the  temperature  unit  from  °C  /  °F 
switch
 (2).
1
2
4.  Place the main lid back on the tubular casing and twist 
it to   (lock position).  
2
1
5.  Press RESET.
USING THE SENSOR
1.  The sensor has a string to loop through the hole at the 
base of the tubular casing. This can allow you to hang 
the unit while you immerse it in water.
2.  Place the sensor in the water and make sure that it is 
within the effective transmission range (328 feet / 100 
metres) from the main unit.
 TIP  Press RESET whenever the sensor is not performing 
as expected (e.g. unable to establish radio frequency link 
with the main unit). 
 TIP  Place the sensor as closely as possible to the main 
unit.    Otherwise,  minimise  obstructions  such  as  doors, 
walls  and  furniture  between  the  main  unit  and  sensor  if 
the sensor cannot be placed close to the main unit. You 
may need to experiment with various locations to get the 
best results.
  NOTE    With  adequate  power,  the  Liquid  Crystal 
Display in outdoor temperatures will remain operational 
up to -28°C (-20°F).
  NOTE    Wireless  ranges  can  be  impacted  by  a  variety 
of factors such as extremely cold temperatures. Extreme 
cold may temporarily reduce the effective range between 
the  sensor  and  the  main  unit.  If  the  unit’s  performance 
fails  due  to  low  temperature,  the  unit  will  resume  proper 
functioning as the temperature rises to within the normal 
temperature  range.  No  permanent  damage  will  occur  to 
the unit due to low temperatures.
BATTERY REPLACEMENT
Replace  the  batteries  whenever  the  low  battery  icon   
shows  on  the  remote  sensor,  or  on  the  remote  sensor 
area  of  the  main  unit.    Press  RESET  after  every  battery 
replacement.
PRECAUTIONS
• 
Do not subject the unit to excessive force, shock, dust, 
temperature or humidity.
• 
Do not cover the ventilation holes with any items such 
as newspapers, curtains etc.
• 
Do  not  clean  the  unit  with  abrasive  or  corrosive 
materials. 
• 
Do  not  tamper  with  the  unit’s  internal  components. 
This invalidates the warranty.
• 
Only  use  fresh  batteries.  Do  not  mix  new  and  old 
batteries.
• 
Images  shown  in  this  manual  may  differ  from  the 
actual display.
• 
When disposing of this product, ensure it is collected 
separately  for  special  treatment  and  not  as  normal 
household waste.
• 
Placement  of  this  product  on  certain  types  of  wood 
may  result  in  damage  to  its  finish  for  which  Oregon 
Scientific will not be responsible. Consult the furniture 
manufacturer's care instructions for information.
• 
The  contents  of  this  manual  may  not  be  reproduced 
without the permission of the manufacturer.
• 
Do  not  dispose  old  batteries  as  unsorted  municipal 
waste.  Collection of such waste separately for special 
treatment is necessary.
• 
Please  note  that  some  units  are  equipped  with  a 
battery safety strip. Remove the strip from the battery 
compartment before first use.
 NOTE  The technical specifications for this product and 
the  contents  of  the  user  manual  are  subject  to  change 
without notice.
SPECIFICATIONS
TYPE
DESCRIPTION
Dimension
100 mm (D) x 180 mm (H)
Weight
174 g
Operating range in 
water
0°C (32°F) to 50°C (122°F)
Operating range in 
room temperature
-30°C (-22°F) to 85°C (185°F)
Temperature 
resolution
0.1°C (0.2°F)
Number of channels
3
Data transfer
- Channel 1:  
approximately every 53 seconds
- Channel 2:  
approximately every 59 seconds
- Channel 3:  
approximately every 61 seconds 
Transmission range
328 ft (100 m)
Transmission 
frequency
433 MHz
Batteries
2 x UM-3 / AA 1.5V
Remote sensor 
waterproof
Up to 1 m (3.28 ft)
ABOUT OREGON SCIENTIFIC
Visit  our  website  (www.oregonscientific.com)  to  learn 
more about Oregon Scientific products. If you’re in the US 
and would like to contact our Customer Care department 
directly, please visit: 
www2.oregonscientific.com/service/support 
OR 
Call 1-800-853-8883. 
For  international  inquiries,  please  visit:  www2.
oregonscientific.com/about/international
EU-DECLARATION OF CONFORMITY
Hereby,  Oregon  Scientific,  declares  that  this  Water 
Thermo  Sensor  (model:  THWR800  /  THWR800A)  is  in 
compliance  with  the  essential  requirements  and  other 
relevant provisions of Directive 1999/5/EC. A copy of the 
signed and dated Declaration of Conformity is available on 
request via our Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVED COMPLIED
All EU countries, Switzerland   CH
and Norway    N
FCC STATEMENT
This  device  complies  with  Part  15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  This 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation.
  WARNING    Changes  or  modifications  not  expressly 
approved  by  the  party  responsible  for  compliance  could 
void the user’s authority to operate the equipment.
  NOTE    This  equipment  has  been  tested  and  found  to 
comply with the limits for a Class B digital device, pursuant 
to Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference 
in a residential installation.
This  equipment  generates,  uses  and  can  radiate  radio 
frequency  energy  and,  if  not  installed  and  used  in 
accordance  with  the  instructions,  may  cause  harmful 
interference  to  radio  communications.  However,  there 
is  no  guarantee  that  interference  will  not  occur  in  a 
particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user 
is encouraged to try to correct the interference by one or 
more of the following measures:
• 
Reorient or relocate the receiving antenna.
• 
Increase  the  separation  between  the  equipment  and 
receiver.
• 
Connect the equipment into an outlet on a circuit different 
from that to which the receiver is connected.
• 
Consult the dealer or an experienced radio / TV technician 
for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for 
support or sales. Please call our customer service number 
(listed on our website at www.oregonscientific.com, or on 
the warranty card for this product) for all inquiries instead.
We
Name: 
 
Oregon Scientific, Inc.
Address:   
19861 SW 95
th
 Ave.,Tualatin,
 
 
 
Oregon 97062 USA
Telephone No.: 
1-800-853-8883
declare that the product 
Product No.: 
THWR800 / THWR800A
Product Name: 
Water Thermo Sensor
Manufacturer: 
IDT Technology Limited
Address:   
Block C, 9/F, Kaiser Estate,
 
      
 
Phase 1, 41 Man Yue St.,    Hung  
 
 
Hom, Kowloon, Hong Kong
is in conformity with Part 15 of the FCC Rules.  Operation 
is  subject  to  the  following  two  conditions:  1)  This  device 
may not cause harmful interference. 2) This device must 
accept  any  interference  received,  including  interference 
that may cause undesired operation.
Sonde-Thermomètre d’Eau
Modèle : THWR800 / THWR800A
MANUEL DE L’UTILISATEUR
FR
FACE AVANT
1
1.  Indicateur LED
FACE ARRIERE
1.  Habitable tubulaire 
2.  Bouton RESET (Réinitialiser)
3.  Fente pour lanière 
AFFICHAGE
1
2
3
1.  Indicateur de canal 
2.  Indicateur de faiblesse des piles
3.  Affichage de la température
INTRODUCTION
Ce capteur est compatible avec les appareils de prévisions 
météorologiques portant ce logo  
.
AU COMMENCEMENT
Vous  trouverez  le  compartiment  des  piles  à  l’intérieur 
de  l’habitacle  tubulaire  et  les  interrupteurs  de  sélection 
des  canaux  et  de  l’unité  de  température  à  l’intérieur  du 
couvercle principal. 
1.  Positionnez le couvercle principal sur   (position de 
déverrouillage) puis retirez-le de l’habitacle tubulaire. 
2.  Retirez le couvercle du compartiment des piles et insérez 
2  piles  UM-3  /  AA  1,5  V  en  respectant  les  polarités.  
Remettez le couvercle du compartiment en place.
1
2
4
3
  REMARQUE    Les  piles  alcalines  standard  sont 
composées  d’un  volume  d’eau  non  négligeable.  Par 
conséquent,  elles  peuvent  geler  lors  de  températures 
inférieures à -12°C (10°F).   Les piles aux lithium ont un 
seuil inférieur lors de températures froides, elle ne peuvent 
en effet geler qu’à -40°C (-40°F).
 IMPORTANT  Ne pas utiliser de piles rechargeables.
 ATTENTION   Même si vous utilisez des piles au lithium 
pour  alimenter  le  capteur,  et  bien  que  le  capteur  puisse 
supporter de faibles températures, il n’est pas recommandé 
THWR800A_M_R0.indd   1
3/20/08   5:06:18 PM