Siemens LC 500 User Manual
Page 6
SITRANS LC 500 – INSTRUCTION MANUAL
7ML19985GE01
mmmm
m
Specificat
ions
Electrodes
Process connections
• threaded connection
AISI 316 L stainless steel, 3/4”, 1”, 1-1/4”, 1-1/2”, 2”, NPT,
BSPT, JIS
• flat-faced flanges
AISI 316 L stainless steel (optional C 22.8 N, Monel
1
400,
Hastelloy
2
C22, Duplex) ANSI, DIN
3
Probe diameter
• Cable: 9
mm
(0.35”)
• Rod:
16 mm (0.63”) or 24 mm (0.95”)
Probe length
• Rod version:
up to 3500 mm (138”) with 16 mm (0.63”) diameter probe
up to 5500 mm (216”) with 24 mm (0.95”) diameter probe
up to 5500 mm (216”) with 24 mm (0.95”) diameter probe
• Cable version:
35 m (15 ft.)
Probe insulation
PFA, Enamel
4
Wetted Parts
Probe insulation
PFA / Enamel
Threaded connection
AISI 316 L stainless steel
Flange
AISI 316 L stainless steel or Teflon
5
covered
Enclosure (electronic)
• construction
aluminum, epoxy-coated; diameter 160 mm (6.3")
• cable entry
2 x 1/2” NPT
• ingress protection
Type 4X / NEMA 4X / IP 65
Weight
Depends on configuration.
Example:
model:
S-series
rod:
PFA insulated, 16 mm (0.63”) dia., 1 m (39.4”) insertion length
weight:
approx. 5 kg
1.
Monel® is a registered trademark of the International Nickel Company.
2.
Hastelloy® is a registered trademark of Haynes International Inc.
3.
on page 90 for a table showing flange sizes.
4.
Only available as Rod version, max. length 1500 mm (59”), and only for use in
applications where pH
applications where pH
≤
7.
5.
Teflon® is a registered trademark of Dupont.