Fluke 1552A EX User Manual

Page of 22
 
Stik Thermometer 
 
SCPI Commands 
13 
Battery Life 
Battery life is approximately 300 hours (12.5 days) of continuous operation with the 
backlight off. A low-battery icon (
E) shows in the lower right of the display when 
battery level is low. Replace batteries per recommendations found in the specifications 
section of this manual. 
Calibration 
For calibration information, refer to the document on the documentation CD. 
SCPI Commands 
For a list of the SCPI commands, refer to the document on the documentation CD. 
RS-232 Interface 
An RS-232 interface is standard on the Product. Serial communication can be used for 
configuration, calibration, and to move measurement data from the Product. An RS-232 
cable is included with data logging software purchase. 
XW
Warning 
To prevent possible electrical shock, fire, or personal injury, the 
RS-232 interface must not be used in hazardous areas. 
Specifications 
(Ambient: 23 
°
±
°
C)  
Measurement Range 
 1551A 
Ex 
.........................................................................
50 
°
C to 160 
°
C (
58 
°
F to 320 
°
F) 
 1552A 
Ex 
.........................................................................
80 
°
C to 300 
°
C (
112 
°
F to 572 
°
F) 
Accuracy (1 year) .....................................................................
±
0.05 
°
C (0.09 
°
F) 
Resolution ................................................................................. Selectable (0.1, 0.01, 0.001) factory default is 0.01 
Sample Rate  ............................................................................. User selectable 0.5/sec, 1/sec or 2/sec factory default is 
1/sec 
Operating Temperature Range of Readout: ..........................
10 
°
C to 50 
°
C (14 
°
F to 122 
°
F) 
Probe Response Time .............................................................. Approximately 20 seconds 
EMC Compliance....................................................................... EN61326:2006 Annex C 
 
CISPR 11, Edition 5.0-2009 
 Class 
“B” 
Humidity Range......................................................................... 0 to 95 % RH Non-condensing 
Storage Temperature Range....................................................
20 
°
C to 60 
°
C (
°
F to 140 
°
F) 
Enclosure Rating ...................................................................... IP50 
Readout Temperature Coefficient ........................................... Add 
±
10 ppm/
°
C of full scale temperature from 
10 
°
C to 
18 
°
C and 28 
°
C to 50 
°
Probe Temperature Coefficient .............................................. 0.00385 
Ω
/
Ω
/
°
C nominal 
Nominal Probe Resistance at 0 
°
.......................................... 100 
Ω
 
Probe Hysteresis.......................................................................
±
0.01 
°
Power ......................................................................................... 3 AAA alkaline batteries  
(Must use only approved batteries. See Table 2)