Generac Power Systems 941-2 User Manual
Section 6.6
OPTIONAL REMOTE PANEL
GENERAL
An optional remote-mounted Start-Stop panel is avail-
able. This panel will permit the generator to be started
and stopped from some convenient remote location in
the recreational vehicle.
able. This panel will permit the generator to be started
and stopped from some convenient remote location in
the recreational vehicle.
REMOTE PLUG-IN RECEPTACLE
A plug-in receptacle (Figure 2.24) is provided on the
generator set, near the DC power wires. Use this
receptacle to connect an optional remote-mounted
start/stop panel to the generator. Installation of such a
panel will permit you to start and stop the generator
engine from any convenient location inside the vehi-
cle.
A plug-in receptacle (Figure 2.24) is provided on the
generator set, near the DC power wires. Use this
receptacle to connect an optional remote-mounted
start/stop panel to the generator. Installation of such a
panel will permit you to start and stop the generator
engine from any convenient location inside the vehi-
cle.
Figure 1. Remote Panel Plug-In Receptacle
REMOTE START/STOP PANEL
A remote mounted Start/Stop panel (Figure 2.25) is
available that allows the user to start and stop the
generator engine conveniently from inside the vehicle.
The remote panel includes a Start/Stop switch,
hourmeter, generator run lamp and a wire harness.
A remote mounted Start/Stop panel (Figure 2.25) is
available that allows the user to start and stop the
generator engine conveniently from inside the vehicle.
The remote panel includes a Start/Stop switch,
hourmeter, generator run lamp and a wire harness.
Figure 2. Optional Remote Panel
(Models 004057 and 004184)
The remote panels mount a rocker type start/stop
switch, a “Generator Run” advisory lamp and an
hourmeter. The hourmeter should be used in conjunc-
tion with the maintenance operations found in Part I of
this manual.
• Model 004057 includes the remote panel and a 10
switch, a “Generator Run” advisory lamp and an
hourmeter. The hourmeter should be used in conjunc-
tion with the maintenance operations found in Part I of
this manual.
• Model 004057 includes the remote panel and a 10
foot long, 4 wire harness.
• Model 004184 includes the remote panel and a 30
foot long, 4 wire harness.
WIRE #18
(STOP)
WIRE #14
(ENGINE RUN
SIGNAL)
WIRE #17
(CRANK)
WIRE #10
(GROUND)
Page 6.6-1