™ Audio Connections 
There are (8) 3.5mm mini-Phoenix inputs and (8) 3.5mm mini-Phoenix outputs on the back panel of 
the unit (four on the 4-
channel system) providing access to each channel‘s audio signal.  
The provided mini-Phoenix connectors are designed for easy wiring. The three terminals (from left to 
right) correspond to positive +, negative -, and shielded ground .  
To connect audio In/Out on the Base Station 
1.  Use the screws on top of the connector to first loosen the terminals. 
2.  Insert an appropriate 3-conductor cable (2 conductors and shield) into the terminals. 
3.  Tighten the screw to secure the cable. 
4.  Push the connector onto the pins centered under the desired input or output port until firmly 
secured. 
 
The microphone output  connectors need to be attached to the line-level  (0dBu) input  connectors of 
an audio mixer. PHANTOM POWER MUST BE OFF. PHANTOM MAY CAUSE DAMAGE TO THE 
BASE STATION

 
The  Base  Station  input  connectors  (also  0dBu)  may  then  be  attached  to  mixer  channel  outputs. 
Because  the  system  is  full-duplex,  the  input  connections  provide  the  ability  to  hear  program  audio 
using a 2.5mm earpiece attached to the microphone (supplied with the wearable microphone).  
Depending on the application, it is possible to feed a single mixed channel back to all earpieces or, 
alternatively, each user can receive a separate and unique channel. This would allow for translation, 
personal hearing assistance or other services to be incorporated into an application. 
 
Configuring the Executive HD
TM
 Base Station 
 
Each  Revolabs  Executive  HD
TM
  Base  Station  must  be  configured  properly  prior  to  use.  Accurate 
configuration is dependent on several variables such as: 
 
1.  How many Executive HD
TM
 systems are being used together in proximity? 
2.  What type of 3
rd
 party mute control is being used? 
3.  How large is the room? 
4.  Is Line Level or Mic Level signal required? 
5.  How do the mic mutes need to function? 
 
Once  these  questions  are  answered,  accurate  configuration  of  the  Executive  HD  base  can  be 
achieved using a combination of the following methods. 
 
Using Multiple Revolabs Executive HD
TM
 Systems Together 
 
If more than one Revolabs Executive HD ™ Base Station is used in an area, each unit needs to be 
interconnected with a synchronization (BUS) cable using a standard 3.5mm mini-Phoenix connector 
and  any  26AWG  or  better,  shielded  cable.  The  maximum  distance  from  the  Primary  unit  to  any 
Secondary device must n
ot exceed 300‘ (90 meters). In addition, DIP switch #1 needs to be adjusted 
on one or more of the units to represent the 