Landice 8700 User Manual

Page of 85
64
Elevation system not functioning or PO (Pot Out) error code displayed in the two digit 
speed window.
Enter the DIAGNOSTIC MODE. (See pages 12, 13, or 14)
Does the elevation system work properly?
Proceed with recalibrating 
elevation potentiometer, page 8.
Unplug 6 pin elevation motor connector from relay board. 
Which button or direction seems to have the problem?
Hold the UP button on the treadmill.
Is UPSW light on the relay board lit?
Hold the DOWN button on the treadmill.
Is DNSW light on the relay board lit?
1.Inspect the Creme wire (UP) and the Pink wire (DOWN) on both the 12 wire connector 
on the relay board and the 14 wire connector on the upper display board for loose 
connections or pushed pins.
2.If all harness connections are intact, then replace Upper Display Board.
Part# 70191-CL (Sprint), Part# 70173-CL (SST), Part# 70196-CL (PRG)
Hold the UP button on the treadmill. 
Is the UP light on the relay board lit?
Hold the DOWN button on the treadmill. 
Is the DN light on the relay board lit?
Do both the UP & DN lights 
on the relay board light?
Replace relay board.
Part# 70213
Do both the UP & DN lights 
on the relay board light?
SYMPTOM
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
UP
DOWN
7.1
7.2
7.3
7.4
1. Inspect the Black wire (UP) and the Red wire (DOWN), on the 6 pin connector, for any loose 
connections or pushed pins.
2. If all harness connections are intact then replace the Elevation Motor. Part# 70088
7.5