16
In case the transmitter battery is running low, a low battery warning 
“LOBT” will be transmitted and displayed intermittently with the pressure 
reading on the Vytec (Fig.2.6 d).
If the dive is started without that the Vytec and the transmitter have been 
properly paired, the Vytec will indicate that no cylinder data is available 
by displaying “OFF”  (Fig. 2.6 e).
TABLE 2.1.  PRESSURE TRANSMISSION RELATED DISPLAYS
 Display  Indication 
Figure 2.6 
  SETC 
Set Code. No code stored, 
   
wrist unit ready for pairing with transmitter. 
  - - - 
Pressure reading over 360 bar [5220 psi] 
  FAIL  
Indicates pressure reading has not been 
   
updated in more than 1 minute. 
   
Transmitter is out of range, in power saving 
   
mode or on another channel. Activate the 
   
transmitter by breathing off the regulator, 
   
and recode the wrist unit if necessary. 
  LOBT 
Indicates pressure transmitter battery voltage 
d
   
is low. Change the transmitter battery!
  OFF 
Pairing has not been conducted before 
   
start of dive. No cylinder data available.