5.8 Special AT Command Set for Java Applications
49
s
wm_java_usersguide_v12
Page 40 of 123
2008-02-25
Confidential / Released
5.8
Special AT Command Set for Java Applications
For the full AT command set refer to 
. There are differences in the behaviour AT commands
issued from a Java application in comparison to AT commands issued over a serial interface.
5.8.1
Switching from Data Mode to Command Mode
Cancellation of the data flow with “+++” is not available in Java applications, see 
 for details.
To break the data flow use breakConnection(). For details refer to 
.
5.8.2
Mode Indication after MIDlet Startup
After starting a module without autobauding on, the startup state is indicated over the serial
interface.  Similarly, after MIDlet startup the module sends its startup state (^SYSSTART,
^SYSSTART AIRPLANE MODE etc.) to the MIDlet. This is done via a URC to the AT Com-
mand API instance which executes the very first AT Command from within Java. To read this
URC it is necessary to register a listener (see 
) on this AT Command API instance before
passing the first AT Command.
5.8.3
Long Responses
The AT Command API can handle responses of AT commands up to a length of 1024 bytes.
Some AT commands have responses longer than 1024 bytes, for these responses the Java
application will receive an Exception.
Existing workarounds:
Instead of listing the whole phone book, read the entries one by one
Instead of listing the entire short message memory, again list message after message
Similarly, read the provider list piecewise
Periods of monitoring commands have to be handled by Java, e.g. AT^MONI, AT^SMONG.
These AT commands have to be used without parameters, e.g. for AT^MONI the periods
must be implemented in Java.
5.8.4
Configuration of Serial Interface 
While a Java application is running on the module, only the AT Command API is able to handle
AT commands. All AT commands referring to a serial interface are ignored. This includes the
commands:
AT+IPR (sets a fixed local bit rate)
AT\Q1, AT\Q2 and AT\Q3 (sets type of flow control)
If Java is running, the firmware will ignore any settings from these commands. Responses to
the read, write or test commands will be invalid or deliver „ERROR“. 
Note: When a Java application is running, all settings of the serial interface are done with the
class CommConnection. This is fully independent of any AT commands relating to a serial
interface.