The Display Panel
1-9
Power is supplied to the chassis via two IEC sockets (the top 
socket serves the left-hand PSU) on a fixed power inlet panel 
fitted in the chassis between the right-hand PSU slot (PSU 2), and 
the module slots. The two sockets provide resilience against 
power supply cable or fuse faults.
The Display Panel
The display panel provides the following features:
Lamps Button
The Lamps button allows you to carry out an LED test which 
shows you that all the LEDs on the display panel and on modules 
installed into the chassis, are working. If an LED on the display 
panel does not light, refer to Chapter 5 of this user guide; if it is a 
problem with a module LED, refer to the user guide that 
accompanies the product.
Reset Button
Pressing the Reset button restarts the MSH. To prevent an 
accidental reset of the modules, the Enter button on the 
four-button keypad must be pressed at the same time as the 
Reset button
.You should only need to reset the MSH immediately after 
installation. It is advisable not to use the Reset button during 
normal operation, as this could cause loss of data.
RS232 Port
This is a 25-way D-Type connector to which you may connect a 
local management terminal directly or via a modem. Note that, in 
order to use this port, a LinkBuilder MSH Management Module 
must be installed into the chassis.
The display panel also gives you simple fault finding with a line of 
comprehensive LEDs, which are explained in Chapters 4 and 5.