3com DUA1800-0AAA04 User Manual

Page of 119
3-10
C
HAPTER
 3: I
NSTALLING
 M
ODULES
 I
NTO
 T
HE
 MSH C
HASSIS
DUA1800-0AAA04
Token Ring Modules
The operation of 3Com token rings is described in Volume 3 of 
the user guide that accompanies the MSH management module.
Token rings in the MSH chassis are built from two types of 
module:
Media Access Unit (MAU)
RingBuilder module
Normally an internal token ring will have one RingBuilder and 
several MAUs linked into it. These modules provide all the 
standard functions within an 802.5 Token Ring network.
The MAU Module
The MAU module (available with UTP or STP connections) 
provides connectivity for a number of ring-stations into an 
internal token ring section. It provides the following functions:
A physical and electrical connection of a token ring-station to a 
local ring section of a token ring network.
Data rates of either 4 or 16 Mbps. It is possible to operate 
separate 4 and 16 Mbps rings simultaneously in the same MSH 
chassis.
Basic insert and bypass functions, together with signal retiming 
for the module.
Port level insertion control capability when a management 
module and an associated RingBuilder module are installed in the 
MSH chassis. This incorporates the ability to enable or disable a 
port, and provides an asynchronous method of notifying the 
management software of any port status change.
Supported lobe lengths of 100 meters at 4 Mbps, 100 meters at 
16 Mbps assuming the use of high quality data grade cable.
Chassis.bk : CHAPTER3  Page 10  Monday, February 10, 1997  1:11 PM