Roland AR-3000R User Manual

Page of 152
 
102
 
Controlling Another Device with the 
AR-3000R (Control Output Terminal)
 
You can control an external device from the AR-3000R by 
using the output connectors among the screw-on control 
terminals on the unit’s rear panel.
The AR-3000R outputs two types of control signals: BUSY 
OUT and CONTROL OUT.
This chapter describes how to connect external equipment 
and make the settings on the AR-3000R.
 
To confirm phrases when making settings, you can use the 
PLAY/STOP button to play and stop phrases and the PAUSE 
button to pause phrases (audio phrases only), and the 
SELECT dial to move the playback location forward and 
backward (audio phrases only). Note that you cannot change 
settings during phrase playback.
 
Also refer to “Examples of Usage and Connection for the AR-
3000R” (p. 19) for more examples of usage of the control 
input and output terminals.
 
For information about the specifications of the control input 
and output terminals, refer to “Specifications of the Control 
Input/Output Terminals” (p. 137).
 
Important Notes on Using the Control Input 
and Output Terminals
 
* The control input and output terminals cannot be used to 
switch the power to the AR-3000R on or off.
 
When making connections to the ports, be careful not to lose 
the removed screws. Place the screws out of the reach of 
small children. If a screw is accidentally swallowed, 
immediately consult a physician.
 
Starting Another Device 
 
(Busy Out)
 
What Is a Busy Out Signal?/
Equipment Connections
 
A Busy Out signal is a signal that is continuously output 
from the BUSY OUT port during playback (and during 
recording and recording standby) of audio phrases, MIDI 
phrases, pattern phrases, and song phrases.
You can use this signal to start an amp or other external 
device in sync with phrase playback.
The setting for whether or not the Busy Out signal is to be 
output is made separately respective to the following three 
situations:
Time ON/OFF
• During phrase playback: in Phrase Play ON/OFF
Repeat Int ON/OFF
The setting is made on a system-wide basis (that is, it cannot 
be made separately for individual phrases).
The Busy Out specifications are no-voltage/make-contact, 
with a contact capacity of a maximum of DC 30 V at 5 A.
 
fig.15-01e (Busy Out Connection)
 
Turning the Power On and Off 
 
 
 
Busy Out Signal Output During Playback of 
Pattern Phrases and Song Phrases 
 
Both pattern phrases and song phrases (p. 62, p. 65) are each 
handled as single phrases, so during playback the Busy Out 
signal is output without interruption.
 
Busy Out Signal Output During Dual Mono 
Mode Playback 
 
During Dual Mono mode playback, the left-channel Busy 
Out signal is output from the BUSY OUT port, and the right-
channel Busy Out signal is output from the CONT OUT port.
 
Dual Mono Mode 
 
 