Panasonic AG-DV2500 User Manual

Page of 68
E-62
OTHERS
– Warning display –
When an anomaly occurs, this unit automatically identifies the cause and displays an error-
coded warning message on the monitor.
If the unit is in a state needing rectification, or if an operation error has occurred, an alarm
display will be shown on the monitor.
3 2 K C H – 1 / 2
 
 
    0
m i n
W A R N I N G 7 0 0 1
D R U M MO T O R F A I L U R E
1 0 / 1 0 / 0 2
S T A N D B Y - O F F
1 2 : 0 0 : 0 0
T C R
0 2 : 0 0 : 0 0 : 0 0
Warning display
3 2 K C H – 1 / 2
 
 
    0
m i n
H E A D C L E A N I N G R E Q U I R E D !
1 0 / 1 0 / 0 2
S T A N D B Y - O F F
1 2 : 0 0 : 0 0
T C R
0 2 : 0 0 : 0 0 : 0 0
Alarm display
 Alarm display (Displayed regardless of the DISPLAY mode)
Display
Status
Action
LOW VOLTAGE
HEAD CLEANING
REQUIRED!
The DC power voltage is low.
The unit will eventually go into the POWER OFF
mode if operation is continued.
The video head is dirty. If the head is clogged, it
will be detected and the alarm message will be
displayed during the PLAYBACK mode. When
the STOP mode is engaged or when the cas-
sette is ejected, the display will go off.
When the head clog is cleared, the message
will disappear.
Please check the power voltage.
Please clean it with the dedi-
cated head-cleaning tape.
(
 Page 8)
If the message persists despite
cleaning, it could be due to bad
recording condition, bad tape or
lifespan of the head.
• For alarm messages displayed upon operation errors or when the unit is in a poor working condition (e.g.
dirty head), refer to page 22.