Chapter 2    Operation and Maintenance 
 
57
Step 5.    Executing CHKDSK (backup server) 
In step 2, separation was executed without specifying a static point.    Execute CHKDSK /F to remove 
inconsistency in file system. 
CHKDSK H: /F 
 
Step 6.    Terminating applications (backup server) 
To maintain data consistency, terminate or halt applications and specified services. 
(Example) Terminating service 
NET STOP (service name) 
To stop the service “ESMCommonService”, specify as shown below. 
NET STOP ESMCommonService 
 
Step 7.    Flushing RV file system (backup server) 
Flush RV file system and write the unwritten data in file system buffer onto disk. 
iSMrc_flush –drv H: 
 
The operation displays the following message and flushes the data. 
Flush Start                2001/02/21 11:21:13 
            disk11                                          dev002                                                  WN 
      \\?\Volume{37d84cca-2507-11d5-a0f7-00004c714491}\ 
            H: 
 
Flush Normal End          2001/02/21 11:21:13 
            disk11                                          dev002                                                  WN 
      \\?\Volume{37d84cca-2507-11d5-a0f7-00004c714491}\ 
            H: 
 
Step 8.    Unmounting RV (backup server) 
Unmount RV and cancel association between volume and file system. 
When the RV is unmounted, the mount point (drive letter or NTFS folder name) set for the volume is 
automatically deleted.    On Windows 2000, the RV access restriction is changed to Not Ready. 
* Set NOTREADY for the UMOUNT_RVACC parameter in the replication operation option setting 
file to suppress automatic RV mounting before operation. 
When executing unmounting, all application software, that may access the drive, must be terminated in 
advance. 
Refer to descriptions about unmounting Chapter 3 “Notes” also. 
iSMrc_umount –drv H: