Check your operating system and patch revision levels
Use the following commands to assist you.
# uname -a
# showrev -p
Install the Storage System
Refer to the appropriate storage system Site Preparation Guide and hardware 
installation documents, as needed. Do NOT, however, attach fibre channel 
cables at this time.
After placing the hardware, refer to the Preconfiguration and Maintenance 
Setup Instructions, P/N 95966, and the Storage Manager Concepts Guide. 
This will enable you to understand the proper configuration for the business 
environment, and to understand how to attach your laptop in order to configure 
the storage system for communications with your management station.
Note: The management station is used to configure and/or verify that the 
LUNs are set up as desired.
If you need more information about configuring LUNs, refer to the software 
installation guide or use the GUI help function.
Install your storage manager GUI onto the customer’s storage management 
station (attached via ethernet), and verify that the LUNs are set up as desired.
Proceed to the next section to verify or install the NVSRAM file to the storage 
system.
Load NVSRAM
1. Verify or install the current NVSRAM (available on the CD in your host 
attach kit) onto the control module (controller). Refer to the Storage 
Manager Concepts Guide, which provides the command for the SMclient:
Storage Array >> Download >> NVSRAM
The following instructions tell how to attach the HBAs and other components 
onto your Solaris host.
Before you perform these instructions, check to see that you:
are running Solaris 2.7, 8, or 9 with the most current patches, as 
required.
have the appropriate installation kit (HBAs, cables, etc.)
know the configuration for your customer’s site.