Tyco Electronics M7100IP User Manual

Page of 80
 
40 
12.5.2 
ProScan 
The radio can be programmed for ProScan™ system scan operation for multi-site applications 
depending on the version of radio flash code. ProScan provides the radio with the ability to select 
a new system for the radio to communicate on, when the selected system drops below a 
predefined level. This is accomplished by enabling each radio to analyze the signal quality of its 
current control channel and compare it with the signal quality of the control channel for each site 
in its adjacency scan list. (The signal quality metric used for the ProScan algorithm is based on a 
combination of both Received Signal Strength Indicator [RSSI] and Control Channel Verification 
[CCV] measurements.)  When the selected system’s signal quality level degrades below a pre-
programmed level, the radio will begin to look for a better control channel. Once a control 
channel that exceeds the pre-programmed parameters is found, the radio will change to the new 
system and emit a tone. If the control channel is completely lost the radio, will enter Wide Area 
System Scanning and search the programmed adjacent systems until a suitable control channel is 
found. 
12.5.3 
Priority System Scan 
The radio can also be programmed for Priority System Scan. (To ensure that this feature operates 
correctly, the control channel of the priority system must be located on channel one unless you are 
using the ProScan algorithm.)  The priority system is the desired or preferred system. While 
receiving the control channel of the selected system, the radio will periodically leave the selected 
system and search for the control channel of the priority system at a programmable rate. The 
programmable rate is defined by the value in the Priority Scan Time control, (unless the 
ProSound/ProScan algorithm is enabled as explained below). This priority scan timer is reset each 
time the PTT button is pressed or when a call is received. If the priority system control channel is 
found, or meets the predefined ProScan criteria, the radio will automatically switch to the priority 
system. 
12.5.4 
When Wide Area System Scan Is Enabled 
If the radio cannot find the control channel of the selected system and begins Wide Area System 
Scan (WA Scan), the radio will only scan for the priority system control channel if the priority 
system is in the WA Scan list. 
12.5.5 
When ProScan Is Enabled 
The radio monitors the priority system and will switch to the priority system if the priority system 
meets the criteria defined in the “ProSound/ProScan Options” dialog box. If ProScan is enabled, 
the rate at which the radio will scan for the priority system is defined by the System Sample Time 
control. 
12.5.6 
Menu Selection 
Press 
M and then use the RAMP controls, , and ., to scroll through the selections until 
SYS SCAN is displayed. Then press 
M to toggle the System Scan state. The SYSC ON or 
SYSC OFF display message is displayed for two seconds to show the new state. 
12.5.7 
Pre-Programmed Keypad Key 
Press the pre-programmed key and the SYSC ON or SYSC OFF display message is displayed 