Honeywell TE831W-2 User Manual

Page of 34
 
 
 
 
32
Range: 0° to 360° 
Resolution: 22.5° 
Accuracy: 11.25° 
Starting Threshold: 3mph (4.8 Km/h) 
Transmitting interval: 33 seconds 
Operating Range: 100 feet (30 m) 
 
Wind Speed 
Range: 0 to 199.9mph (199.9 Km/h, 173.7 Knots, 89.3 m/s) 
Resolution: 0.1mph (0.16 Km/h) 
Accuracy: (2mph + 5%) 
Starting Threshold: 3mph (4.8 Km/h) 
Wind/Gust Speed Display Update Interval: 33 seconds 
Wind/Gust Sampling Interval: 11 seconds 
Operating Range: 100 feet (30 m) 
 
Rainfall 
1h/24h/yesterday range: 0 to 78.73 inch (0 to 1999.9 mm) 
Last week/ last month range: 0 to 787.3 inch (0 to 19999 mm) 
Resolution: 0.03 inch (0.6578 mm) 
Accuracy: +/- 5% +/- 0.03 inch (+/-5%mm +/-0.6875) 
Transmitting Interval: 183 seconds 
Operating Range: 100 feet (30 m) 
 
Hardware Requirement for WeatherCapture PC software   
Operating System: Windows 98/NT/2000/ME, XP or Vista 
Memory size: Ram 128 MB or more 
Hard disk size: 100 MB free space or more 
Media Device: 1 x CD-Rom drive 
Available serial USB port 
 
Power (12 AA Batteries) - included 
Main unit: 4 x UM-3 or AA 1.5V battery; 7.5V AC/DC power adaptor (200mA; center pin positive) 
(2)Remote Thermo Hygrometer: 2 x UM-3 or AA 1.5V battery 
Remote Anemometer: 2 x UM-3 or AA 1.5V battery 
Remote Rain Gauge: 2 x UM-3 or AA 1.5V battery