OVERVIEW
KEY BUTTONS (FIG. 1)
1. 
 : Set alarm and snooze on / off
2. 
 : Set altitude
3. 
  :  Increase  settings  for  altitude  setting;  select 
temperature and altitude unit
4. 
 : Decrease settings for altitude setting
5. 
 : Snooze alarm; activate backlight
6. 
 : Increase settings for clock (
 for BA200A)
7. 
 : Decrease settings for clock; receive clock signal
8. 
 : Set clock
9. 
 : Set and display alarm time
LCD DISPLAY (FIG. 2)
1.  Indicate alarm function is enabled
2.  Indicate snooze function is enabled
3.  Alarm time display 
4.  Clock signal reception indicator
5.  Indicate Daylight Saving Time
6.  Weather forecast and pressure trend 
GETTING STARTED
INSERT BATTERIES (FIG. 3)
Batteries  serve  as  back  up  power  supply.    For  continuous 
use of LCD backlight, always plug in the adapter.  
1.  Remove the battery compartment.
2.  Insert the batteries, matching the polarities (+ / -).
3.   Press RESET after each battery change.
CLOCK 
CLOCK RECEPTION
This product is designed to synchronize its clock automatically 
with a clock signal:
• 
EU:  DCF-77  signal:  within  1500  km  (932  miles)  of 
Frankfurt, Germany.
• 
UK:  MSF-60  signal:  within  1500  km  (932  miles)  of 
Anthorn, England.
• 
US:  WWVB-60  signal:  within  3200km  (2000  miles)  of 
Fort Collins Colorado. Manually set clock to select time 
zone (Pacific, Mountain, Central or Eastern).
To manually activate / deactivate a clock signal:
Press and hold 
 .
 NOTE  Reception takes 2-10 minutes. If the signal is weak, 
it can take up to 24 hours to get a valid signal.
 NOTE  
• 
To ensure good reception of clock signal, place the unit 
near  a  window  and  keep  it  away  from  metal  surfaces 
and electrical appliances.
• 
Do  not  operate  the  unit  over  a  steel  desk  or  metal 
surface, as this will interfere with clock signal reception.
Clock signal reception indicator:
GOOD SIGNAL
WEAK SIGNAL
MANUALLY SET CLOCK
For BA200:
1.  Press and hold 
.
2.  Press 
 or 
 to change the settings.
3.  Press 
 to confirm.
4.  The settings order is: hour, minute, second, year, month, 
date and time zone. The weekday will match automatically.
 NOTE  •  Time zone offset sets the clock +/- 12 hours from  
 
  the received clock signal time.  
 
 
•  Press 
 to select 12 / 24 hour format.
For BA200A:
1.  Press 
 to select time zone: (P) Pacific, (E) Eastern, 
(C) Central or (M) Mountain.
2.  Press and hold  .
3.  Press 
 or 
 to change the settings.
4.  Press   to confirm.
5.  The  settings  order  is:  D-T/S-T,  12/24  hr,  hour,  minute, 
second, year, month and date. The weekday will match 
automatically.
 NOTE  “D-T” means Daylight Saving Time and “S-T” means 
Normal Time.
ALARM
To set the alarm:
1.  Press and hold  .
2.  Press 
 (
 for US) or 
 to set hour and minute. 
3.  Press   to confirm. 
 indicates alarm is  activated.
To toggle alarm and snooze On / Off:
Press 
  indicates  alarm  is  activated,  whereas 
indicates snooze is activated.
To silence the alarm:
• 
Press 
  to  silence  it  for  5  minutes. 
  will  flash 
continuously.
OR
• 
Press any other key to turn the alarm off. 
PRESSURE
To select barometer measurement unit:
Press 
 to toggle between mb/hPa and inHg.
SET ALTITUDE
Input the altitude of the location for an accurate pressure analysis.
1.  Press and hold  .
2.  Use 
 or   to set the altitude in 10 m (30 ft) increments 
from -300 m (-900 ft) to 1200 m (3600 ft).
3.  Press   to confirm.
PRESSURE TREND
RISE
STEADY
FALL
 NOTE  After inserting the batteries or resetting the unit, please 
allow 12 hours for the unit to record the incoming air pressure 
data for calculating and analysing the weather forecast.
WEATHER FORECAST
This  product  forecasts  the  next  12  to  24  hours  of  weather 
within a 30-50 km (19-31 mile) radius.
 
Sunny
Partially cloudy
Cloudy
Rainy
Stormy
TEMPERATURE
To toggle temperature unit:
Press 
.
BACKLIGHT
Press 
 to activate the backlight for a few seconds.
  NOTE    The  backlight  will  always  be  turned  on  when  the 
power adapter is used (OPTIONAL).
RESET
Press the RESET hole at the back of the unit to return to the 
default settings.
PRECAUTIONS
• 
Do not subject the unit to excessive force, shock, dust, 
temperature or humidity.
• 
Do not cover the ventilation holes with any items such as 
newspapers, curtains etc.
• 
Do not immerse the unit in water. If you spill liquid over 
it, dry it immediately with a soft, lint-free cloth.
• 
Do not clean the unit with abrasive or corrosive materials. 
• 
Do not tamper with the unit’s internal components. This 
invalidates the warranty.
• 
Only use fresh batteries. Do not mix new and old batteries.
• 
Images shown in this manual may differ from the actual 
display.
• 
When  disposing  of  this  product,  ensure  it  is  collected 
separately for special treatment.
• 
Placement  of  this  product  on  certain  types  of  wood 
may  result  in  damage  to  its  finish  for  which  Oregon 
Scientific  will  not  be  responsible.  Consult  the  furniture 
manufacturer's care instructions for information.
• 
The  contents  of  this  manual  may  not  be  reproduced 
without the permission of the manufacturer.
• 
Do  not  dispose  old  batteries  as  unsorted  municipal 
waste.  Collection  of  such  waste  separately  for  special 
treatment is necessary.
• 
Please  note  that  some  units  are  equipped  with  a 
battery  safety  strip.  Remove  the  strip  from  the  battery 
compartment before first use.
  NOTE    The  technical  specifications  for  this  product  and  the 
contents of the user manual are subject to change without notice.
SPECIFICATIONS
TYPE
DESCRIPTION
L x W x H
168 x 64 x 113 mm (6.61 x 2.52 x 4.45 in)
Weight
330 g (11.6 oz) without battery
Indoor temperature
 
range
-9°C to 70°C (15.8°F to 158°F)
Resolution
0.5°C (1°F)
Barometer 
measurement range
800 – 1050 mbar
Calendar
2000 - 2099
Power
3 x UM-4 (AAA) 1.5 V batteries
DC 4.5V power adapter
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more 
about  Oregon  Scientific  products.  If  you’re  in  the  US  and 
would like to contact our Customer Care department directly, 
please visit: www2.oregonscientific.com/service/support 
OR 
Call 1-800-853-8883. 
For international inquiries, please visit: www2.oregonscientific.
com/about/international
FCC STATEMENT
This  device  complies  with  Part  15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: (1) This 
device  may  not  cause  harmful  interference,  and  (2)  This 
device  must  accept  any  interference  received,  including 
interference that may cause undesired operation.
  WARNING    Changes  or  modifications  not  expressly 
approved by the party responsible for compliance could void 
the user’s authority to operate the equipment.
 NOTE  This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to Part 15 of 
the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation.
This  equipment  generates,  uses  and  can  radiate  radio 
frequency energy and, if not installed and used in accordance 
with  the  instructions,  may  cause  harmful  interference  to 
radio  communications.  However,  there  is  no  guarantee 
that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct 
the interference by one or more of the following measures:
• 
Reorient or relocate the receiving antenna.
• 
Increase the separation between the equipment and receiver.
• 
Connect  the  equipment  into  an  outlet  on  a  circuit  different 
from that to which the receiver is connected.
• 
Consult the dealer or an experienced radio / TV technician for help.
DECLARATION OF CONFORMITY
The  following  information  is  not  to  be  used  as  contact  for 
support or sales. Please call our customer service number 
(listed on our website at www.oregonscientific.com or on the 
warranty card for this product) for all inquiries instead.
We
Name: 
Oregon Scientific, Inc.
Address: 
19861 SW 95
th
 Ave.,Tualatin,
 
Oregon 97062 USA
Telephone No.: 
1-800-853-8883
declare that the product 
Product No.: 
BA200 / BA200A
Product Name: 
Radio Controlled Clock with  
 
Weather Forecast
Manufacturer: 
IDT Technology Limited
Address: 
Block C, 9/F, Kaiser Estate,
 
Phase 1,41 Man Yue St., Hung  
 
Hom, Kowloon, Hong Kong
is in conformity with Part 15 of the FCC Rules.  Operation is 
subject to the following two conditions: 1) This device may 
not cause harmful interference. 2) This device must accept 
any  interference  received,  including  interference  that  may 
cause undesired operation.
EN
Horloge radio pilotée avec 
prévisions météo
Modèle : BA200 / BA200A
MANUEL DE L’UTILISATEUR
VUE D’ENSEMBLE
BOUTONS PRINCIPAUX (FIG. 1)
1. 
  :  Règle  l’alarme  et  active/désactive  le  rappel 
d’alarme
2. 
 : Règle l’altitude
3. 
 : Augmente les paramètres du réglage de l’altitude, 
sélectionne les unités de température et d’altitude
4. 
 : Diminue les paramètres du réglage de l’altitude
5. 
: Active le rappel d’alarme et le rétro-éclairage. 
6. 
 : Augmente les paramètres de l’horloge (
 pour 
le modèle BA200A)
7. 
  :  Diminue  les  paramètres  de  l’horloge,  reçoit  le 
signal d’horloge
8. 
 : Règle l’horloge
9. 
 : Règle et affiche l’heure de l’alarme
ECRAN LCD (FIG. 2)
1.  Indique que la fonction alarme est activée
2.  Indique que la fonction rappel d’alarme est activée
3.  Affiche l’heure de l’alarme
4.  Indicateur de réception du signal de l’horloge 
5.  Indique l’heure avancée (heures d’hiver ou d’été)
6.  Prévisions météorologiques et variation de la pression 
atmosphérique
POUR COMMENCER
MISE EN PLACE DES PILES (FIG. 3)
Les  piles  n’ont  qu’une  fonction  d’alimentation  de  secours.  
Si vous désirez utiliser continuellement le rétro éclairage de 
l’écran LCD, veuillez brancher l’adaptateur secteur.  
1.  Retirez le couvercle du compartiment des piles. 
2.  Insérez les piles, en respectant les polarités (+ / -).
3.   Appuyer  sur  RESET  chaque  fois  que  les  piles  ont  été 
remplacées.
HORLOGE
RÉCEPTION DE L’HORLOGE
Ce  produit  est  conçu  pour  synchroniser  automatiquement 
l’horloge avec le signal radio :
• 
EU : Signal DCF-77 : dans un rayon de 1500 Km (932 
miles) depuis Frankfort, Allemagne.
• 
UK : Signal MSF-60 : dans un rayon de 1500 Km (932 
miles) depuis Anthorn, Angleterre.
• 
US : Signal WWVB-60 : dans un rayon de 3200 km (2000 
miles) de Fort Collins, Colorado. Réglez manuellement 
l’horloge  pour  sélectionner  le  fuseau  horaire  (heure 
Pacifique, des montagnes, Centrale ou côte Est
Pour  activer/désactiver  manuellement  le  signal  de 
l’horloge:
Appuyez et maintenez le bouton 
.
 REMARQUE  La réception prend de 2 à 10 minutes. Si le 
signal est faible, 24 heures peuvent être nécessaires pour 
obtenir un signal valide.
 REMARQUE 
• 
Pour  assurer  une  bonne  réception  du  signal  radio  de 
l’horloge, placez l’appareil près d’une fenêtre et éloignez 
le des surfaces métalliques et appareils électriques.
• 
Ne  faites  pas  fonctionner  l’appareil  sur  un  bureau  ou 
une  surface  métallique,  ceci  créerait  une  interférence 
avec la réception du signal de l’horloge. 
 
Indicateur de réception du signal de l’Horloge :
BON SIGNAL
SIGNAL FAIBLE
REGLER MANUELLEMENT L’HORLOGE
Pour BA200 :
1.  Appuyez et maintenez le bouton 
.
2.  Appuyez sur 
 ou 
 pour modifier les réglages.
3.  Appuyez sur 
 pour confirmer. 
4.  Les  réglages  s’effectuent  dans  l’ordre  suivant :  Heure, 
minute, seconde, année, mois, date et fuseau. Les jours 
de la semaine correspondront automatiquement.
 REMARQUE 
• 
La  fonction  de  fuseau  horaire  règle  l’horloge  à  +/-  12 
heures de l’heure du signal reçu.  
• 
Appuyez sur 
 pour sélectionner le format de l’heure 
12 / 24.
Pour BA200A :
1.  Appuyez sur 
 pour sélectionner le fuseau : Heure 
Pacifique  (P),  Côte  Est  (E),  Centrale  (C)  ou  des 
Montagnes (M).
2.  Appuyez et maintenez le bouton 
.
3.  Appuyez sur 
 ou 
 pour modifier les réglages.
4.  Appuyez sur 
 pour confirmer. 
5.  Les  réglages  s’effectuent  dans  l’ordre  suivant :  D-
T/S-T,  12/24  H,  heure,  minute,  seconde,  année,  mois 
et  date.  Les  jours  de  la  semaine  correspondront 
automatiquement.
 NOTE  “D-T” signifie heure avancée (été) et “S-T” correspond 
aux heures normales (hiver).
L’ALARME
Pour régler l’alarme :
1.  Appuyez et maintenez le bouton 
.
2.  Appuyez  sur 
  (
  pour  US)  ou 
  pour  régler 
l’heure et les minutes. 
3.  Appuyez sur 
 pour confirmer. 
 
indique que l’alarme 
est activée. 
Pour  alterner  entre  activer/désactiver  l’alarme  et  le 
rappel d’alarme :
Appuyez sur 
 indique que l’alarme est active, alors 
que 
 indique que le rappel d’alarme est activé.
Pour couper le son de l’alarme :
• 
Appuyez sur 
 pendant 5 minutes pour couper le 
son de l’alarme. 
 clignotera en continu.
OU
• 
Appuyez sur n’importe quel autre bouton pour éteindre 
la sonnerie du réveil. 
PRESSION
Pour sélectionner l’unité de mesure du baromètre :
Appuyez sur 
 pour passer de la pression atmosphérique 
en mb à celle en inHg.
RÈGLE L’ALTITUDE
Entrez  l’altitude  de  votre  localisation  pour  une  analyse 
précise de la pression. 
1.  Appuyez et maintenez le bouton 
.
2.  Utilisez 
 ou   pour régler l’altitude par incréments 
de 10 m (30 pieds) de -300 m (-900 pieds) à 1 200 m 
(3600 pieds).
3.  Appuyez sur 
 pour confirmer. 
VARATION DE PRESSION
AUGMENTATION
STABLE
DIMINUTION
 NOTE  Après avoir inséré les piles ou réinitialisé l’appareil, 
attendez  12  heures  pour  que  l’appareil  enregistre  les 
données  d’entrée  des  pressions  atmosphériques  afin  de 
pouvoir analyser et donner les prévisions météo.
PRÉVISIONS MÉTÉOROLOGIQUES
Ce  produit  vous  permet  de  connaître  les  prévisions 
météorologiques pour les prochaines 12 à 24 heures dans 
un rayon de 30 à 50 Km (19-31 miles).
 
Ensoleillé
Partiellement nuageux
Nuageux
Pluvieux
Orageux
TEMPÉRATURE
 Pour sélectionner l’unité de température :
Appuyez sur 
.
FR
1
4
5
2
6
3
BA200A_USA_M_R1.indd   1
8/15/07   11:04:29 AM