Alliance Laundry Systems 907003062 User Manual

Page of 52
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
70420801 (EN)
24
Figure 3 
How to Adjust Gas Valve Governor/Regulator
1. Check gas burner orifice (manifold) pressure as 
follows. Refer to Figure 3.
2. Remove screw plug from inside pressure tap.
3. Connect a “U”-tube manometer (or similar 
pressure gauge) to the orifice (manifold) pressure 
tap.
4. Start tumble dryer and note pressure once flame 
is burning. Remove regulator cap and adjust 
regulator screw until the burner orifice pressure 
per applicable table is achieved. Replace 
regulator cap.
5. Commission tumble dryer for use.