American Dryer Corp. ADG-385 User Manual

Page of 57
5
AS  REQUIRED
In cleaning and care of the cabinet, avoid using harsh abrasives.  A
product intended for the cleaning of appliances is recommended.
B. Adjustments
SUGGESTED INTERVAL
FUNCTION
6 MONTHS
Motor and drive belts should be examined.  Cracked or seriously
frayed belts should be replaced.  Tighten loose belts when necessary,
and check belt alignment.
6 MONTHS
Complete operational check of controls and valves.
6 MONTHS
Complete operational check of  ALL safety devices (door switches,
sail switch, burner and lint chamber thermostats.)
12 MONTHS
Inspect bolts, nuts, screws, non-permanent gas connections,
(unions, orifices, etc.) electrical terminals, and grounding
connections.
C. Lubrication
The motor bearings, idler bearings and tumbler bearings are permanently lubricated, and no lubrication is
necessary.