Single Drop Timer
NOTE: The following information is for 
models with an SD control suffix only.
Power-Up Mode
When power is applied to the tumbler, the IN USE 
light flashes factory status information. Following this, 
the control goes into READY Mode (light off) or RUN 
Mode if power was interrupted during a cycle (light 
on, time remaining unchanged).
Ready Mode
In READY Mode (light off), the control waits for the 
vend to be satisfied. When vend is satisfied the control 
goes into START Mode.
Start Mode
In START Mode (light on), the vend has been satisfied 
but the start button has not been pressed. Time 
remaining in the cycle will not change until the start 
button is pressed. When the start button is pressed the 
machine goes into RUN Mode.
Run Mode
In RUN Mode (light on), the machine is running a 
cycle and the time remaining is counting down. When 
time remaining counts down to zero, the control goes 
into READY Mode.
Setting Dry Time Dipswitches
To change the dry time on the tumbler, combinations 
of dipswitches can be set on the control.
There are eight dipswitches on the tumbler control. 
The first six switches are used to program the amount 
of additional heat time given for each coin pulse. The 
additional drying time is added to the factory default 
minimum heat time of one minute. A valve of 1 to 64 
minutes of additional drying time is available for each 
coin drop pulse.
The last two switches are used to program the amount 
of additional cool down time. The additional cool 
down time is added to the factory default minimum 
cool down time of 1 minute. A value of 1 to 3 
additional minutes is available. The control is shipped 
from the factory programmed with 1 minute of 
minimum heat time, preset with 7 additional minutes 
of drying time (dipswitches 1, 2 and 3 in ON position) 
and 1 minute of minimum cool down time for a total 
time of 9 minutes for a coin pulse. For dipswitch 
settings refer to Table 13.
The control reads the dipswitch settings at power-up. 
The control must be powered down to change the 
dipswitch settings. 
To change the time for a coin pulse, the desired dry 
time dipswitches must be set to ON position. All other 
dipswitches must be in OFF position.