Haier HDG5300AW User Manual

Page of 107
1. Only rigid metal duct work should be used.
2.  Venting vertically through a roof may expose the exhaust system to down 
drafts causing an increase in vent restriction.
3.  Running the exhaust system through an uninsulated area may cause 
condensation and faster accumulation of lint.
4.  Compression of crimping of the exhaust system will cause an increase in  
vent restriction.
5.  In Canada, that only those foil-type flexible ducts, if any, specifically identified 
for use with the appliance by the manufacturer shall be used. In the United 
States, that only those foil-type flexible ducts, if any, specifically identified 
for use with the appliance by the manufacturer and that comply with the UL 
Outline for clothes Dryer Transition Duct, Subject 2158A (2006), shall be 
used. 
6.  In Canada, that the exhaust duct shall be 102 mm in diameter. In the United 
States, the required exhaust duct diameter. 
 The exhaust system should be inspected and cleaned a minimum of every 12 
months with normal usage. The more the dryer is used the more often you should 
check the exhaust system and vent hood for proper operation. 
 
Side and Bottom Exhaust 
For your convenience, your dryer can be exhausted through the side or the 
bottom. If you need to change the exhaust on the dryer to the side or the 
bottom of the cabinet, you will need to order the exhaust kit from your Haier 
dealer or call 1- 800-313-8495
English
8
  
RECOMMENDED MAXIMUM
Exhaust Hood Types
Recommended
Use only for short
run installations
No. of 90º
elbows
Rigid Metal
Rigid Metal
0
90 ft.
60 ft.
1
60 ft.
45 ft.
2
45 ft.
35 ft.
3
35 ft.
25 ft.
The total length of flexible metal duct shall not exceed 
 
 
94 inches.