4-Wire Direct Wire Connection 
IMPORTANT: 
A 4-wire connection is required for mobile 
homes and where local codes do not permit 3-wire 
connections. 
2.
 
Prepare to connect neutral 
     ground wire and neutral wire
E
A
B
Remove center terminal block screw (B). Remove neutral 
ground wire (E) from external ground conductor screw (A).
Unscrew the removable conduit connector (A) and any  
screws from a 3/4" (19 mm) UL listed strain relief (UL marking 
on strain relief). Put the threaded section of the strain relief 
(C) through the hole below the terminal block opening (B). 
Reaching inside the terminal block opening, screw the 
removable conduit connector (A) onto the strain relief threads.
A
B
C
1.
 
Attach direct wire strain relief
Put direct wire cable through the strain relief. The strain 
relief should have a tight fit with the dryer cabinet and be in 
a horizontal position. Tighten strain relief screw against the 
direct wire cable.
2.
  
Attach direct wire cable to strain 
relief 
Direct wire strain relief
Direct wire cable must have 5 ft. (1.52 m) of extra length so 
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,  
leaving bare ground wire at 5" (127 mm). Cut 1
1
/
2
" (38 mm)  
from remaining 3 wires. Strip insulation back 1" (25 mm).  
Shape ends of wires into hooks.
     1"
(25 mm)
       5"
(127 mm
)
1.
 
Prepare your 4-wire cable for  
     direct connection
Direct Wire Connection
3-wire direct connection:
Go to “3-Wire Direct Connection”  
on page 11.
4-wire direct connection:
Go to “4-Wire Direct Connection”  
on this page. 
If your wiring looks like this: