2.   Insert a UL listed strain relief into the mounting bracket hole. Position the strain 
relief so that one tab is pointing up and one tab is pointing down. Tighten the 
strain relief screws just enough to hold the two halves together.
  Tab
  Strain Relief
A
B
3.   Insert a power cord into the strain relief. Take care to ensure that the wire 
insulation of the power cord is inside the strain relief.
4.   Connect power cord wires following Part A for a 4-wire power cord 
connection or Part B for a 3-wire power cord connection. 
4-wire (recommended) if your home has a 4-wire receptacle (NEMA 
14-30 type SRDT or ST):
3-wire (if 4-wire is not available) if your home has a 3-wire receptacle 
(NEMA 10-30 type SRDT):
CAUTION:  A 4-wire connection is required for mobile homes and 
where local codes do not permit the use of 3-wire connections. 
5.   Tighten strain relief screws.
6.   Be sure that none of the wires are touching the dryer drum inside the dryer 
cabinet.
7.   Reinstall the terminal block cover.
PART A - 4-WIRE POWER CORD
A
B
C
F
G
D
E
  Green Ground Screw
  Terminal Block Screw
  Power Cord Wires (One Red; One
          Black)
  White (Neutral) Power Cord Wire
  Power Cord
  Green Power Cord Ground Wire
  Green (Neutral) Ground Wire From
          the Dryer Harness