Haier RDG350AW User Manual

Page of 90
18
8.   Check all connections for leaks by applying a noncorrosive leak-detection 
solution.  Bubbles will identify leaks.  If leaks are found, close the shut-o   valve, 
retighten the joint, open the shut-o   valve, and check again.
WARNING
Never use an open flame to test for gas leaks.
STEP 3 - CONNECT TO AN EXHAUST SYSTEM
WARNING
To reduce the risk of fire, this dryer must be exhausted outdoors.
1.   Make sure that the exhaust system is free and clear of old lint accumulation prior 
to connecting the dryer.
2.   Use 4” (102 mm) rigid or ß exible metal ducting to connect the dryer exhaust 
outlet to the exhaust system.
3.   Use clamps to seal and secure all joints. Exhaust ducting must not be connected 
with screws or other fastening devices which extend into the interior of the duct.
NOTES: 
   Do not use plastic or metal foil ß exible ducting.  Excessive lint can build up inside 
the ductwork, restrict airß ow, and create a Þ re hazard.  Restricted air ß ow will 
increase drying time.
   The dryer must not be exhausted into a gas vent, chimney, wall, ceiling or other 
concealed space of a building. The dryer must be exhausted to the outdoors. 
If the dryer is not exhausted outdoors, some Þ ne lint will be expelled into the 
laundry area. An accumulation of lint in any area of the home can create a health 
and Þ re hazard.