Australia, use only the caster supplied by the manufacturer for the fryer 
device.  The fryer must be installed using a hose assembly restraining device to 
limit the movement of the appliance in accordance with AS1869. 
 
 
The fryer must be installed with a connector (not supplied by Hobart)  
complying with the above codes. 
 
 
The fryer must be installed with restraining means to guard against  
transmission of strain to the connector.  See illustration. 
 
 
The fryer must be installed with the casters provided. 
 
 
If the restraint is ever to be disconnected, turn off electric supply to the fryer. 
 
 
ELECTRICAL CONNECTION 
 
     
Electrical and Grounding connections must comply with the National Electrical Code  
      and/or other local codes. 
 
      Disconnect the electrical power supply to the machine and follow lockout / tag out  
      procedures. 
 
      Appliances equipped with a 120V flexible electric supply cord are provided with a three- 
      prong grounding plug.  It is imperative that this plug be connected into a properly 
      grounded three-prong receptacle.  If the receptacle is not the proper grounding type,  
      contact an electrician. Do not remove the grounding prong from this plug. 
 
 
 
For 480 volt fryers a separate cord and NEMA 15-5P plug is required (not supplied with 
the fryer).  Plug in the wire connection into an approved outlet. 
 
Place fryer as near to its final position as possible.  Connect 3 phase line to X, Y and Z on 
terminal block. To reach terminal block, remove electric cover plate from fryer. 
 
For each 15½” (39 cm) and 21” (53 cm) section, a 3 phase supply line capable of handling 
the required KW at the fryer’s rated voltage (208, 240, and 480) is needed.  Refer to the 
fryer data plate for this electrical information.  
 
                  To shield electric connection supply wiring, a permanently connected or direct 
wired device must be installed using flexible conduit sleeve with the appropriated 
connectors.