KitchenAid KEHS01P User Manual

Page of 72
13
Optional 3-wire connection
Use for direct wire or power supply cord where local codes 
do not permit connecting cabinet-ground conductor to 
neutral wire.
1. Remove center terminal block screw.
2. Remove neutral grounding wire (green with yellow stripes) 
from external ground conductor screw. Connect appliance 
ground wire and the neutral wire (white or center wire) of 
power supply cord/cable under center, silver-colored terminal 
block screw. Tighten screw.
3. Connect the other wires to outer terminal block screws. 
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external 
ground conductor screw to an adequate ground.
Venting Requirements
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
4" (10.2 cm) heavy metal exhaust vent and clamps must be used. 
DURASAFE™ vent products are recommended.
DURASAFE™ vent products can be purchased from your dealer 
or by calling Whirlpool Parts and Accessories. For more 
information, see the “Assistance or Service” section of this 
manual.
The dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, or a concealed space of a building.
Do not use an exhaust hood with a magnetic latch.
Do not install flexible metal vent in enclosed walls, ceilings or 
floors.
Use clamps to seal all joints. Exhaust vent must not be 
connected or secured with screws or other fastening devices 
which extend into the interior of the duct. Do not use duct 
tape.
IMPORTANT: Observe all governing codes and ordinances.
Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended to prevent crushing and 
kinking.
Flexible metal vent must be fully extended and supported when 
the dryer is in its final position. Remove excess flexible metal vent 
to avoid sagging and kinking that can result in reduced airflow 
and poor performance.
An exhaust hood should cap the vent to prevent rodents and 
insects from entering the home.
Exhaust hood must be at least 12" (30.5 cm) from the ground or 
any object that is in the path of the exhaust (such as flowers, 
rocks or bushes, etc.).
If using an existing vent system, clean lint from the entire length 
of the system and make sure exhaust hood is not plugged with 
lint. Replace any plastic or metal foil vent with rigid metal or 
flexible metal vent.
A. External ground conductor screw
B. Neutral grounding wire (green with yellow stripes)
C. Neutral wire (white or center wire)
D. Grounding path determined by a qualified electrician
A
B
C
D
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
Improper venting can cause moisture and lint to collect 
indoors, which may result in:
Moisture damage to woodwork, furniture, paint, 
Housecleaning problems and health problems.
  wallpaper, carpets, etc.