Routing and Connecting Ductwork
Follow the guidelines below to maximize drying 
performance and reduce lint buildup and 
condensation in the ductwork.
NOTE: Ductwork and fittings are NOT included 
and must be purchased separately.
•  Use 4-in. (10 cm) diameter rigid or semirigid 
metal ductwork.
•  The exhaust duct run should be as short as 
possible.
•  Use as few elbow joints as possible.
•  The male end of each section of exhaust duct 
must point away from the dryer.
• Use duct tape on all duct joints. 
•  Insulate ductwork that runs through unheated 
areas in order to reduce condensation and lint 
buildup on duct surfaces.
IMPORTANT: Failure to exhaust the dryer 
correctly will void the dryer’s warranty.
VENTING THE DRYER
 (cont.)
Correct Venting
Incorrect Venting
 
 
Number of  
Max. Length of 4-In. Dia. 
Max. Length of 4-In. Dia.  
 
Wall Cap Type 
90° Elbows 
Rigid Metal Duct 
Flexible Metal Duct
 
 
65 ft. (19.8 m) 
45 ft. (13.7 m)
 
 
55 ft. (16.8 m) 
35 ft. (10.7 m)
 
 
47 ft. (13.7 m) 
30 ft. (9.1 m)
 
 
36 ft. (11.0 m) 
25 ft. (7.6 m)
 
 
28 ft. (8.5 m) 
20 ft. (6.1 m)
 
  
55 ft. (16.8 m) 
35 ft. (10.7 m)
 
 
47 ft. (13.7 m) 
27 ft. (8.1 m)
 
 
41 ft. (12.5 m) 
21 ft. (6.4 m)
 
 
30 ft. (9.1 m) 
17 ft. (5.2 m)
 
 
22 ft. (6.7 m) 
15 ft. (4.5 m)
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended to use more than four 90° elbows.
4"
(10.2 cm)
2
1
/
2
"
(6.35 cm)
4"
(10.2 cm)
Recommended
Use Only for Short 
Run Installations
Ductwork